background image

DTF – 1960 Series Operator Manual

 

5

INSTALLATION & STACKING INSTRUCTIONS (if applicable) 

 

Other than the optional legs, this unit is ready for operation after uncrating.  In the event that you ordered a “double-
stack” of two Dual Technology Finishers, stacking brackets will be required to properly anchor the equipment 
together.  When stacking appliances, it is required that two stacking brackets be properly attached to the units to 
ensure a proper fit and connection. 
 
 
 
 
 
 
 
 

DTF STACKING BRACKET 
Part Number: 7008811 

Stacking Brackets have been designed to align with 
the screw openings for the DTF covers (upper and 
lower).  Two brackets are required for each set of 
appliances and may be placed either on the front or 
back of the appliances. 
 
Utilize the following instructions to properly stack the 
DTF units together. 
 
1.  Turn each unit off and unplug each unit from its 

power source. 

2.  Remove the two screws from the “Unit Top” of the 

bottom appliance.  

3.  Remove the legs from the top appliance.  Remove 

the two screws from the “Unit Bottom” of the top 
appliance. 

4.  Gently lower the top unit onto the bottom unit 

making sure to align the screw holes of the “Unit 
Top” and “Unit Bottom.” 

5.  Once the appliances have been aligned, align the 

holes in the Stacking Bracket to the holes in the 
top and bottom DTF appliances.  Reinsert the 
screws so that the Stacking Bracket connects the 
top and bottom units together.  Repeat this step 
with the second Stacking Bracket.  The DTF units 
are now properly stacked.   

6.  Plug each unit into its appropriate power source 

and turn on to begin operation. 

Location of Stacking Brackets (shown 
on front of oven in this case). 

 

WARNING: 

!

Two stacking brackets must be used when stacking two DTF units together.  A 
maximum of two units may be stacked together. 

Содержание 1960 Series

Страница 1: ...ica Technical Support Hotline 800 678 9511 Telephone 260 459 8200 www lincolnfp com operator manual This document includes Safety Notices Specifications Installation Instructions Operating Instruction...

Страница 2: ...the consignee Other Countries Freight terms will be developed and extended on an individual basis Proper and secure storage facilities should be arranged for the unit s if necessary to protect against...

Страница 3: ...ble code requirements Refer to Code References section for more information 5 The fixed supply wiring insulation must be protected against high interior surface temperatures TABLE OF CONTENTS IMPORTAN...

Страница 4: ...0 1964 11 5kW 220V 37 5 3 50 REQUIRED CLEARANCE The unit must have 6 inches 152 mm of clearance from combustible surfaces In case other equipment is located on the right side of the unit a minimum cle...

Страница 5: ...tack the DTF units together 1 Turn each unit off and unplug each unit from its power source 2 Remove the two screws from the Unit Top of the bottom appliance 3 Remove the legs from the top appliance R...

Страница 6: ...all switches should be closed together SPACING The unit must have 6 inches 152mm of clearance from combustible surfaces In case other equipment is located on the right side of the unit a minimum clea...

Страница 7: ...n be used for other menu item programs 3 Programming the unit to desired settings To enter the program mode press and hold the UP BUTTON for 5 seconds The UP and DOWN BUTTONS will light indicating the...

Страница 8: ...ailable selections The BOTTOM I R icon follows the 8 available selections 3 Set TEMPERATURE UNITS C or F a Press and hold BUTTON 1 for 20 seconds to change the C or F value b To change again repeat st...

Страница 9: ...se through previous next parameter in the list b If parameter value is displayed use the UP and DOWN buttons to change the parameter value to within the allowed limits 2 Select the parameter to be adj...

Страница 10: ...s while the appliance is in operation Turn unit off wait 30 minutes for cool down then unplug the unit from its power source 2 Clean exterior surfaces of the appliance by wiping it down with a mild de...

Страница 11: ...n cleaner Let sit for 15 20 minutes use 3M green scrub pad to remove debris Rinse and let dry 2 By releasing the turn fasteners Figure A remove the four Air Wash Assemblies Figure B Please note that t...

Страница 12: ...either end of unit Figure A Slide the Finger Cover from Finger Housing remove Inner Columnating Panel Figure B Clean all pieces with commercial oven cleaner and rinse Allow time to dry before reinstal...

Страница 13: ...ment has been cleaned and allowed to dry reassemble in reverse order Proper placement of the finger assemblies is critical to the operation of the unit Positioning pin must be aligned with the positio...

Страница 14: ...st discuss this need for preventive maintenance with your Authorized Service Company to establish a proper program If there are any questions that the Service Company cannot answer contact Lincoln s T...

Страница 15: ...CT POWER TEMPERATURE HEAT CONVEYOR FAN BURNER HEAT CYCLE READY TIMER INDICATOR RESET HIGH TEMPERATURE HEAT CAUTION HOT SURFACE CLOCK TIME SWITCH TIMER TRANSFORMER DANGEROUS VOLTAGE EQUIPOTENTIALITY GR...

Страница 16: ...DTF 1960 Series Operator Manual 16 LABEL DEFINITIONS CONT D AMPS VOLTS KILOWATTS HR TYPE OF GAS AC COOK TIME SERVICE ACCESSIBILITY PROVIDE MINIMUM REAR AND SIDE CLEARANCE ORIFICE MAIN ORIFICE LOW FIRE...

Страница 17: ...s associated therein null and void This includes any damage costs or legal actions resulting from the installation of any Lincoln commercial cooking equipment in a non commercial application or instal...

Страница 18: ...DTF 1960 Series Operator Manual 18 This page intentionally left blank...

Страница 19: ...DTF 1960 Series Operator Manual 19 This page intentionally left blank...

Страница 20: ...DTF 1960 Series Operator Manual 20...

Отзывы:

Похожие инструкции для 1960 Series