OPERATION
B-18
B-18
RANGER 300 D AND 300 DLX
120/240 V DUAL VOLTAGE RECEPTACLE
The 120/240 V receptacle can supply up to 50 amps
of 240 V power to a two wire circuit, up to 50 amps of
120 V power from each side of the three wire circuit,
(up to 100 amps total). Do not connect the 115 V cir-
cuits in parallel. Current sensing for the automatic idle
feature is in both legs of the three wire circuit as shown
below.
FIGURE B.5
120 V DUPLEX RECEPTACLES
The 120 V auxiliary power receptacles should only be
used with three wire grounding type plugs or approved
double insulated tools with two wire plugs.
MAXIMUM CURRENT DRAW FROM
120 V DUPLEX RECEPTACLES - NO WELDING
EACH HALF OF
EACH 120 V
DUPLEX
TOTAL FROM
ONE 120 V
DUPLEX
TOTAL FROM
BOTH 120 V
DUPLEXES
240 V LOAD FROM
FULL KVA
RECEPTACLE
0
20 AMPS
30 AMPS
40 AMPS
50 AMPS
15 AMPS
15 AMPS
15 AMPS
15 AMPS
0
30 AMPS
30 AMPS
30 AMPS
20 AMPS
0
60 AMPS
60 AMPS
40 AMPS
20 AMPS
0
MAXIMUM CURRENT DRAW FROM OPTIONAL
120 V GFCI DUPLEX RECEPTACLES - NO WELDING
EACH HALF OF
EACH 120 V
DUPLEX
TOTAL FROM
ONE 120 V
DUPLEX
TOTAL FROM
BOTH 120 V
DUPLEXES
240 V LOAD FROM
FULL KVA
RECEPTACLE
0
35 AMPS
50 AMPS
15 AMPS
15 AMPS
0
15 AMPS
15 AMPS
0
30 AMPS
30 AMPS
0
GND
120 V
120 V
240 V