RETEST AFTER REPAIR
Retest a machine:
•
If it is rejected under test for any reason that requires you to remove any mechanical part which could affect
the machine’s electrical characteristics.
OR
•
If you repair or replace any electrical components.
ENGINE OUTPUT
Mode
No Load RPM
Load RPM
Low Idle
2150 - 2220
NA
High Idle
3700 - 3650
3450-3670
WELDER DC OUTPUT
Ou
t
put Control
Range Switch
Open Circuit
Load Volts
Load Amps
Volts
Maximum
Maximum
64 - 74
25 - 35
295 - 325
WELDER AC OUTPUT
Ou
t
put Control
Range Switch
Open Circuit
Load Volts
Load Amps
Volts
Maximum
Maximum
70 - 79
27 - 35
295 - 325
WELDER CV OUTPUT
Ou
t
put Control
Range Switch
Open Circuit
Load Volts
Load Amps
Volts
Maximum
Wire Feed CV High
62 - 71
27 - 34
295 - 325
Maximum
Wire Feed CV Med HI
46 - 53
25 - 30
220 - 240
Maximum
Wire Feed CV Med LO
46 - 53
20 - 25
155 - 170
Maximum
Wire Feed CV Low
46 - 53
15 - 20
135 - 155
AUXILIARY POWER OUTPUT
230 Volt Receptacle
115 Volt Receptacle
Open Circuit
Load Volts
Load Amps
Open Circuit
Load Volts
Load Amps
Voltage
Voltage
245 - 260
210 - 245
48 - 53
120 - 127
106 - 121
58 - 63
AMPHENOL AUXILIARY OUTPUT
42 Volt Auxiliary
115 Volt Auxiliary
Open Circuit
Load Volts
Open Circuit
Load Volts
Voltage
Voltage
40 - 46
38 - 42
115 - 128
114 - 126
TROUBLESHOOTING & REPAIR
F-72
F-72
RANGER 300 D AND 300 DLX