A-5
INSTALLATION
COMPRESSED AIR CONNECTION
(PRISM
®
DOWN DRAFT WITH MECHANIZED
CLEANING
The downdraft table cleaning mechanism functions on
compressed air with a recommended supply pressure of 70-120
psi (5-8 bar). If required, mount a pressure reducing valve to
prevent overpressure.
The internal pressure regulator is factory set to ensure a working
pressure between the values of 65-70 psi (4.5-5 bar).
If the pressure is too high, the safety valve of the system will be
opened, thus decreasing the pressure until the system pressure
has reached an appropriate level.
1. Connect the downdraft table to compressed air. See Figure
A.9, item C. Connection is a 1/4 inch male industrial quick-
connect pneumatic nipple.
FIGURE A.9 – CONNECTIONS
WORK GRID
To mount the standard work grid, proceed as follows. See Figure
A.10
1. Be sure that the prefilters and diffusion plates are in place,
and all foam sheet packing material has been removed.
2. Place the work grids into position.
3. Place the locking clamp over both work grids.
4. Tighten the locking clamp using (2) M6 x 20 Philips head
screws.
NOTE:
It is necessary to install the bracket to ground the work
grids.
FIGURE A.10
A
B
C
PRISM
®
DOWN DRAFT
& PRISM
®
DOWN DRAFT WITH MECHANIZED CLEANING