6. Connect SCR into the test circuit as shown
in
Figure F.8.
(A)Lead to anode (C) lead to
cathode and (G) lead to the gate.
7. Close switch SW-1 (Switch SW-2 should be
open). The voltmeter should read zero. If
the voltmeter reads higher than zero, the
SCR is shorted.
8. With switch SW-1 closed, close switch SW-2
for two seconds and release. The voltmeter
should read 3 to 6 volts before and after
switch SW-2 is released. If the voltmeter
does not read, or reads only while SW-2 is
depressed, the SCR or battery is defective.
(Repeat Battery Test Procedure described in
Step 5.)
9. Open switch SW-1, disconnect the gate lead
(G) and reverse the (A) and (C) leads on
the SCR. Close switch SW-1. The voltmeter
should read zero. If the voltage is higher
than zero, the SCR is shorted.
10. Replace any SCRs that do not pass the
test. See
SCR Bridge Assembly
Removal and Replacement.
11. Replace plug J4 on the control board.
12. Replace the case sides and top.
DIODE D1
SCR4 CATHODE
SCR3 / SCR4 ANODE
SCR3 CATHODE
SCR2 ANODE
SCR1 / SCR2 CATHODE
SCR1 ANODE
LIFT BAIL STABILIZER