DIGITAL DISPLAY
DIGITAL DISPLAY
(SET)
DISPLAY
(SELECT)
DISPLAY
7a
a MENU BUTTON AND DISPLAY SWITCH (C
odes
above 11000
) – Pressing and holding the
(Menu)
Button for about 5 seconds
enters the menu display
which allows:
•
Selection of up to seven programmable parameters
(Preflow, Upslope, Hot Start, Arc Force, etc.) on the
digital meter is achieved by momentarily pressing
and releasing the
MENU
button to step through the
parameters.
•
Setting of the desired level, displayed on the digital
meter for the selected parameter, is done by press-
ing the
DISPLAY
(momentary) switch toggle to the
right to increase the level setting, or to the left to
decrease it.
Setting:
Selection 1:
0
1 *
2
Selection 2:
0
1
2 *
3
4
5
Selection 3:
0 *
1
2
∆
Description:
HF
(High Freq.)
Scratch start TIG (No Hi-Freq.)
Normal Hi-Freq. start and weld
Lift TIG (Touch start w/o Hi-Freq.)
PF
(Preflow time)
No Preflow
0.1 sec.
0.5 sec.
1.0 sec.
1.5 sec.
2.0 sec.
SS
(MicroStart™ Start Pulse)
No AC pulse/Low DC pulse (soft start)
High AC/DC pulse (forceful start)
HS
setting (see below) for each pulse when Pulse
mode welding anodized aluminum.
TIG Mode Menu
Setting:
Selection 4:
0 *
1
2
3
4
5
6
7
8
9
Selection 5:
0
1*
2
3
4
5
Description:
HS
(TIG Hot Start % of output setting)
+0% (Only setting for
SS0
, above.)
+10%
+20%
+30%
+40%
+50%
+60%
+70%
+80%
+90%
UP
(Upslope Time)
None (Only setting for
SS1
&
SS2
, above.)
0.5 sec.
1.0 sec.
1.5 sec.
2.0 sec.
2.5 sec.
TIG Mode Menu (with Advanced Control Panel installed):
*
Default Factory Setting. (Indicated by "blinking" decimal point.)
*
Default Factory Setting. (Indicated by "blinking" decimal point.)
∆
Only selectable with Advanced Control Panel installed.
Setting:
Selection 6:
0
1
2
3
4
5 *
6
7
8
9
Selection 7:
0
1 *
2
3
4
5
6
7
8
9
Description:
HS
(Stick Hot Start % added to output setting)
+0%
+10%
+20%
+30%
+40%
+50%
+60%
+70%
+80%
+90%
AF
(Stick Arc Force % added to output setting)
+0% ("Softer" arc)
+10%
+20%
+30%
+40%
+50%
+60%
+70%
+80%
+90% ("Crisper" arc)
STICK Mode Menu (with Advanced Control Panel installed
◊
):
*
Default Factory Setting. (Indicated by "blinking" decimal point.)
◊
If no Advanced Control Panel the Stick menu
displays “- - -“.
• Any of the following actions will
exit
the menu display:
1. Pressing and holding the
(Menu)
Button again for about 5 seconds.
2. Allowing the menu display to be unchanged for about 15 seconds.
3. Closing the arc start switch (TIG Mode) or starting the arc (Stick Mode).
Note: In Stick Mode the machine output will remain on while in menu display.
•
Re-entering
the menu displays the last parameter and setting that was displayed when the menu was
exited
.
• All settings may be reset to the Factory Default Settings (above) by holding the
(Menu)
button pressed while
turning on the machineʼs
Power
switch. The display will show
“rES”