B-10
OPERATION
B-10
PRECISION TIG 275
Return
to
Section
TOC
Return
to
Section
TOC
Return
to
Section
TOC
Return
to
Section
TOC
Return
to
Master
TOC
Return
to
Master
TOC
Return
to
Master
TOC
Return
to
Master
TOC
FIGURE B.3
2 Step Trigger Modes
2 Step - Restart Disabled
2 Step - Restart Enabled
Torch
Button
Output
Current
Gas
Pre-Flow
Post Flow
Normal Sequence
Torch
Button
Output
Current
Gas
Pre-Flow
Post Flow
START/CRATER CURRENT
UP-SLOPE
DOWN-SLOPE
(With DIP Switch #2 OFF)
(With DIP Switch #2 ON. As Shipped)
Actuate the trigger a second
time, during down-slope, to
immediately end down-slope.
Hold the trigger to maintain
crater current.
Torch
Button
Output
Current
Gas
Pre-Flow
Post Flow
Actuate the trigger a second
time, during down-slope, to
activate up-slope and restart.
2 Step.eps
12-17-07