English
22
English
Figure 57.
Confirm the select – press the Right Button [36]. The
factory settings are restored.
Diagnostic Information
Available information:
Software Version
Hardware Version
Welding Software
Ethernet IP Address
Power Source Protocol
Event Logs
Fatal Logs.
Advanced setup
This menu enables access to the
configuration parameters of the device. To
set the configuration parameters:
Access to the Settings and Configuration Menu.
Use the Right Knob [36] to highlight the
“configuration menu” icon.
Figure 58.
Press the Right Knob [36]. The Configuration Menu
is shown on the display.
Use the Right Knob [36] to highlight the Parameter
Number which will be changed, for example P.1 -
allows change WFS units, factory default:
"Metric" = m/min.
Figure 59.
Press the Right Knob [36].
Use the Right Knob [36] to highlight the in/min
(English/Imperial).
Figure 60.
Confirm the select – press the Right Button [36].