TROUBLESHOOTING & REPAIR
F-41
F-41
POWER WAVE 455M/MSTT
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
FIGURE F.12 – RECEPTACLE S7 TRIGGERED
POWER WAVE CURRENT TRANSDUCER TEST
(CONTINUED)
RECEPTACLE
S7
STT
POWER
WAVE
5. Turn on the Power Wave 455. Check for the
correct DC supply voltage to the current
transducer at plug J8. See
Figure F.11.
A. Pin 2 (lead 212+) to pin 6 (lead 216-)
should read +15 VDC.
B. Pin 3 (lead 213-) to pin 6 (lead 216+)
should read -15 VDC.
If the DC supply voltages are not present,
the control board may be faulty.
6. If both of the supply voltages are low or
missing, check the associated leads
between plug J8 and current transducer plug
P91 and the Control Board.
NOTE:
The machine can be triggered by
jumpering pin 1 to pin 2 at receptacle
S7. See Figure F.12.
7. With the Power Wave 455 triggered, check
the feedback voltage from the current trans-
ducer. The current feedback voltage can be
read at plug J8 on the Control Board.
A. Pin 1 (lead 211) to pin 6 (lead 216)
should read 2.0 VDC (machine loaded
to 250 amps).