![Lincoln Electric Power Wave 455M/STT Robotic Скачать руководство пользователя страница 110](http://html1.mh-extra.com/html/lincoln-electric/power-wave-455m-stt-robotic/power-wave-455m-stt-robotic_service-manual_1918434110.webp)
TROUBLESHOOTING & REPAIR
F-64
F-64
POWER WAVE 455M/MSTT
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
INPUT
CONTACTOR
601
X4
CB4 CIRCUIT
BREAKER &
115V RECEPTACLE
LEADS 33/32
P50
P52
FIGURE F.21 – AUXILIARY TRANSFORMER NO. 2 REMOVAL AND REPLACEMENT
AUXILIARY TRANSFORMER NO. 2 REMOVAL AND
REPLACEMENT PROCEDURE
(CONTINUED)
REMOVAL PROCEDURE
1. Remove input power to the Power Wave
455.
2. Using the 3/8” nut driver, remove the case
top, and input access panel.
3. Perform the
Capacitor Discharge
proce-
dure.
4. Using the 3/8” nut driver, remove the case
back.
5. Disconnect plugs P50 and P52.
6. Disconnect leads 33 and 32 to circuit breaker
CB2 and the 115 V receptacle.
7. Using the 3/8” nut driver, remove the two
transformer mounting screws.