TROUBLESHOOTING & REPAIR
F-28
F-28
POWER WAVE 455M/MSTT
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
J42
J41
J43
4 5 6
3 4
7 8 9 10 11 12
J42
J41
J43
1 2 3
1 2
1 2 3 4 5 6
FIGURE F.8 – POWER BOARD TEST
POWER BOARD TEST
(CONTINUED)
TEST PROCEDURE
1. Remove input power to the Power Wave
455M.
2. Using the 3/8” nut driver, remove the case
top.
3. Perform
the
Capacitor Discharge
Procedure.
4. Locate the Power Board and plugs J42 and
J43.
Do not remove plugs or leads from
the Power Board
. Refer to Figure F.8.
5. Carefully apply input power to the Power
Wave 455M.
ELECTRIC SHOCK can kill.
High voltage is present when
input power is applied to the
machine.
6. Turn on the Power Wave 455M. Carefully
test for the correct voltages at the Power
Board according to
Table F.3.
7. If either of the 40 VDC voltages is low or not
present at plug J41, perform the
DC Bus
PC Board Test
. See the Wiring Diagram. If
indicated, perform the
T1 Auxiliary
Transformer Test.
8. If any of the DC voltages are low or not pre-
sent at plugs J42 and/or 43, the Power
Board may be faulty.
9. If power board is replaced, reassemble and
test machine.
WARNING