9
Lightly pull the start-up knob until meeting resistance,
then pull decisively.
ATTENTION:
Allow the start-up knob to re-enter slowly, avoiding
having it knock against the motor and thereby damaging
the start-up system.
4-
Once the engine is started, with the starter off,
let it turn for a few minutes before drawing the
load
Stopping:
to stop the engine in an emergency, simply turn the engine
switch to the OFF position.
Under normal conditions, use the following procedure:
1) Interrupt welding
1) Stop to draw single-phase current from the auxiliary
sockets.
2) Wait for a few minutes to allow the machine to cool off,
take however into consideration the prescriptions given
in the engine use manual.
3) Turn the engine switch to the OFF position.
4) Shut the gasoline cock.
Use as a generator
AUXILIARY GENERATION IN AC 115V/230V 50Hz
The auxiliary output is drawn by means of a 3 pole
sockets, the two poles are live, phase and neutral, plus
the earth for the machine.
The single phase generation of the machine was
designed to supply small power tools (grinders, drills
etc.) to assist the welding operations with a quick, safe
connection without the need to connect to earth. In
addition, supplying only one tool at a time, the protection
against indirect contact is assured by “electrical
separation”.
Therefore, the machine MUST NOT be intentionally
connected to earth, attaching cables must be of 3 wires
and the electrical equipment on which it being used must
have an extension length limited to 100-200 meters. This
limitation of circuit extension length is fundamental for
safety.
The cables must be SUITED to the environment in which
they are to be used. Bear in mind that at temperatures
below 5°C PVC cables become rigid and the PVC
insulation tends to split at the first crease.
Using double insulated equipment is advisable, this is
identifiable by the symbol and for having no earth facility.
If the machine is designed to supply circuits which are
particularly complex or in an area with potential electrical
risk, it is required to interpose a complete electrical
distribution panel, equipped with all electrical protections
required, between the plug and loads.
For example: you can use a distribution system TN-S. In
this case one of the phases, used as a neutral must be
grounded; a bipolar 30mA differential switch (GFI) must
be mounted inside the electrical box, before the sockets
to which loads are connected; the terminal in the frontal
panel of the generating set near the socket is to be used
as earth connection, wiring it to the ground of the
ENGLISH