8
FUEL
further connection instructions in the section entitled
"Standby Power Connections" as well as the article on
grounding in the latest National Electrical Code and the
local code.
In general, if the machine is to be grounded, it should be
connected with a #8 or larger copper wire to a solid earth
ground such as a metal water pipe going into the ground
for at least ten feet and having no insulated joints, or to
the metal framework of a building which has been
effectively grounded.
The National Electrical Code lists a number of alternate
means of grounding electrical equipment. A machine
grounding stud marked with the symbol
is provided on
the front of the welder.
Welding Output Cables
With the engine off connect the electrode and work cables
to the output studs. The welding process dictates the
polarity of the electrode cable. These connections should
be checked periodically and tightened with a 19mm
wrench.
Table below lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
Combined Length and sizes of cables
Cable Length
Cable Size for 170 A @
60%Duty Cycle
0-30 meters
25mmq
30-46 meters
25mmq
46-61 meters
35mmq
Cable Installation
Install the welding cables to your OUTBACK 200 CE as
follows:
1. The engine must be OFF to install welding cables.
2. Connect the electrode holder and work cables to the
weld output terminals. The terminals are identified
on the case front.
3. Tighten the flanged nuts securely.
4. Be certain that the metal piece you are welding (the
“work”) is properly connected to the work clamp and
cable.
5. Check and tighten the connections periodically.
WARNING
Loose connections will cause the output terminals to
overheat. The terminals may eventually melt.
Do not cross the welding cables at the output
terminal connection. Keep the cables isolated and
separate from one another.
Installation of metal brackets dedicated
to the welding cables management
To facilitate the management of the welding cables take
the four metal brackets from the endowment present in
the packaging and fix them to the generator using the
supplied screwsas indicated in the below picture
Auxiliary Power
The auxiliary power capacity is :
3.300W Peak,3000W continuous of 50Hz at
230Vac .
2.100W Peak ,1800W continuous of 50Hz at
110vac.
Starting and stopping the Engine
Starting:
1-
Turn the fuel cock to ON
2-
Switch the choke control to CLOSE
3-
Turn the engine switch to the ON position
Содержание OUTBACK 200 CE