TROUBLESHOOTING & REPAIR
F-23
F-23
LN-9 GMA Wire Feeder
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
STARTING PROBLEMS
The arc voltage appears to rise too
slowly or stubs or blasts at the start
of a weld. Once started the weld-
ing is good.
NOTE: Pulse Power 500 operation
with a filter kit may exhibit these
symptoms.
1. Adjust the "start" trimmer on the
voltage PC board. It should be
slightly higher than the weld
voltage. See
Starting Charac-
teristics in the Operation section
of this manual.
3. Put the Lincoln power source in
the "Machine Control" mode.
Jumper the "BYPASS" pins on
the LN-9 GMA voltage PC
board. Adjust the weld voltage
from the power source for the
process being used. If the cor-
rect voltage cannot be set, the
power source may be faulty.
4. Check for correct control cable
connections to the power supply.
1. The voltage PC board may be
faulty. Replace.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.