![Lincoln Electric LN-9 GMA Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/lincoln-electric/ln-9-gma/ln-9-gma_service-manual_1918302049.webp)
WIRE FEEDER ACCESSORIES
BURNBACK TIMER KIT (K419)
Provides a precise control of the electrode burnback
at the end of the weld. Prevents crater sticking and
provides proper stickout for starting the next weld.
Recommended especially when welding with small
(0.023-1/16") diameter wire at high wire feed speeds.
Also includes a cold inch switch. (Can be installed
only in GMA models.)
Install the kit according to the M15060 instructions
included with the kit.
ACCESSORIES
C-5
C-5
LN-9 GMA Wire Feeder
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
GUN AND CABLE ASSEMBLIES
A variety of standard Lincoln and Magnum gun and
cable assemblies are available for the LN-9 GMA in
10 ft., 12 ft. and 15 ft. cable lengths. Choose the gun
and cable assembly to suit the LN-9 GMA welding
application and wire size. See Table C-1.
TABLE C.1 – LN-9 GMA GUN AND CABLE ASSEMBLIES
60% Duty
Process
Model
Electrode
Rating
Gas Metal Arc (GMA)
K426
.035-.052” (0.9-1.3 mm) solid
350 amps
.045-
5
⁄
64
” (1.1-2.0 mm) cored
350 amps
K427
.045-
1
⁄
16
” (1.1-1.6 mm) solid
500 amps
1
⁄
16
-
5
⁄
64
” (1.6-2.0 mm) cored
500 amps
Magnum K470
(1)
.035-
1
⁄
16
” (0.9-1.6 mm) solid
300 amps
.035-
5
⁄
64
” (0.9-2.0 mm) cored
300 amps
Magnum K471
(1)
.035-
1
⁄
16
” (0.9-1.6 mm) solid
400 amps
.035-
5
⁄
64
” (0.9-2.0 mm) cored
400 amps
Magnum K478
(2)
.035-
1
⁄
16
” (0.9-1.6 mm) solid
300 amps
.035-
5
⁄
64
” (0.9-2.0 mm) cored
300 amps
Magnum K479
(2)
.035-
1
⁄
16
” (0.9-1.6 mm) solid
400 amps
0.35-
5
⁄
64
” (0.9-2.0 mm) cored
400 amps
Innershield
®
K126
.068-
5
⁄
64
” (1.7-2.0 mm) Innershield
350 amps
K115
5
⁄
64
” (2.0 mm) lnnershield
450 amps
K206
(3)
.068-
5
⁄
64
” (1.7-2.0 mm) Innershield
350 amps
K289
(3)
5
⁄
64
” (2.0 mm) lnnershield
500 amps
K309
(3)
.068-
5
⁄
64
” (1.7-2.0 mm) lnnershield
250 amps
Submerged Arc
K112
1
⁄
16
” (1.6 mm) Solid
500 amps
(1)
K466-1 connector kit required.
(2)
K489 Fast-Mate™ Adapter required.
(3)
Linconditioner™ guns are recommended for locations where smoke accumulation is a problem and conven-
tional exhaust systems are ineffective. The available smoke removal type Innershield guns and vacuum units
can be used in these locations. Instructions are shipped with the equipment.