![Lincoln Electric LN-9 GMA Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/lincoln-electric/ln-9-gma/ln-9-gma_service-manual_1918302133.webp)
TROUBLESHOOTING & REPAIR
F-69
F-69
LN-9 GMA Wire Feeder
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
RETEST AFTER REPAIR
Retest the LN-9 GMA wire feeder:
If it fails any test and the test requires removing
or replacing any mechanical part that could
affect the wire feeder's electrical characteristics.
OR
If you repair or replace any electrical compo-
nent.
The wire feeder must meet the following standards under retest:
Wire Feed Speed, LN-9 GMA ...........................................................................................80 - 980 IPM
Voltmeter .....................................................................................Refer to
Voltmeter Accuracy Check
Wire Speed Meter.....................................................................Refer to
Meter Circuit Accuracy Test
Gas Solenoid .....................................................................Must function when gun trigger is activated
Voltage control and shutdown..................................Refer to
Out of Voltage Range Shut Down Test