TECHNICAL SPECIFICATIONS
–
INVERTEC
®
CC400-S/-S PLUS
INPUT
– THREE PHASE ONLY
INVERTEC
®
CC400-S/-S
PLUS
Standard Voltage/Phase/Frequency
380V ~ 415V(±10%)/3/50 or 60 Hz
Input Power at Rated Output
17KW @ 60% Duty Cycle
RATED OUTPUT
– DC ONLY
INVERTEC
®
CC400-S/-S
PLUS
Duty Cycle
60%
100%
Amperes
400A
310A
Volts at Rated Amperes
36V
32.4V
OUTPUT
INVERTEC
®
CC400-S/-S
PLUS
Welding Current Range
10A ~ 400A
Open Circuit Voltage
68V @380V Input
73V @415V Input
Welding Voltage Range
20.2 V ~ 36V
RECOMMENDED INPUT WIRE AND FUSE SIZES
INVERTEC
®
CC400-S/-S
PLUS
Input
Voltage/
Frequency
(Hz)
380/415V
Maximum
Input
Ampere
38/30A
Maximum
Effective
Supply
Current
29/23A
60°C Copper
Wire in
Conduct
Sizes
6mm
2
Fuse or
Breaker Size
(Super Lag)
40A
Grounding
Conductor
Size
4mm
2
PHYSICAL DIMENSIONS
INVERTEC
®
CC400-S
INVERTEC
®
CC400-S
PLUS
Height
480mm
Width
350mm
Depth
730mm
Weight
32Kg
36Kg
Temperature Range
Operating Temperature Range
-10°C ~ +40°C
Storage Temperature Range
-25°C ~ +55°C