English
English
15
Technical Specifications
INPUT
Input Voltage
400V
15%
Three Phase
Input Power at Rated Output
EMC Class
Frequency
50/60Hz
300TPX
6.5kW @ 100% Duty Cycle (Stick)
5.1kW @ 100% Duty Cycle (TIG)
9.8kW @ 40% Duty Cycle (Stick)
8.1kW @ 40% Duty Cycle (TIG)
A
400TPX
10.8kW @ 100% Duty Cycle (Stick)
7.6kW @ 100% Duty Cycle (TIG)
16.4kW @ 35% Duty Cycle (Stick)
11.9kW @ 35% Duty Cycle (TIG)
A
RATED OUTPUT AT 40°C
Duty Cycle
(Based on a 10 min. period)
Output Current
Output Voltage
300TPX
100% (Stick)
100% (TIG)
40% (Stick)
40% (TIG)
200A
220A
270A
300A
28.0Vdc
18.8Vdc
30.8Vdc
22.0Vdc
400TPX
100% (Stick)
100% (TIG)
35% (Stick)
35% (TIG)
300A
300A
400A
400A
32.0Vdc
22.0Vdc
36.0Vdc
26.0Vdc
OUTPUT RANGE
Welding Current Range
Maximum Open Circuit Voltage
300TPX
5 – 270A (Stick) / 5 – 300A (TIG)
65Vdc (CE model)
12Vdc (AUSTRALIA model)
400TPX
5 – 400A
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse (delayed) or Circuit Breaker (“D” characteristic) Size
Input Power Cable
300TPX 20A
4x2.5mm
2
400TPX 30A
4x4mm
2
PHYSICAL DIMENSIONS
Height Width Length Weight
300TPX 389mm
247mm
502mm
21kg
400TPX 455mm
301mm
632mm
35kg
Operating Temperature
-10°C to +40°C
Storage Temperature
-25°C to +55°C
WEEE
07/06
English
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)
and its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will protect the environment and human health!
Spare Parts
12/05
Part List reading instructions
Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service
Department for any code number not listed.
Use the illustration of assembly page and the table below to determine where the part is located for your particular
code machine.
Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate
a change in this printing).
First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that
contains a picture-descriptive part number cross-reference.