English
English
13
List of parameters and Factory stored programs
List of parameters and Factory Configuration program:
Parameter
Factory Configuration
(P99)
Selectable Value Range
Displayed
parameter
name
Displayed
value
Preflow
0.1s
0 - 5s (step 0.1s)
Current
selected value
(s)
Start Current
Lift TIG 2-step: 22A
Not adjustable
Current
selected value
(A)
Lift TIG 4-step: 100%
HF TIG 2-step: 100%
HF TIG 4-step: 100%
5 - 200%
Upslope
0.5s
0 - 5s (step 0.1s)
Current
selected value
(s)
Set Current
5A
5 - 270A (Stick) (300TPX)
5 - 300A (TIG) (300TPX)
5 - 400A (400TPX)
Voltage at
output studs
Current
selected value
(A)
Duty Cycle
50%
10 - 90% (step 5%)
(f>300Hz Duty=50% 300TPX)
(f>200Hz Duty=50% 400TPX)
Current
selected value
(%)
Frequency (f)
0.1Hz
0.1 - 10Hz (step 0.1Hz)
10 - 300Hz (step 1Hz)
300 - 500Hz (step 10Hz)
Current
selected value
(Hz)
Background
30%
10 - 90% (step 1%)
Current
selected value
(%)
Downslope
0s
0 - 20s (step 0.1s)
Current
selected value
(s)
Crater
30%
5 - 100%
Current
selected value
(A)
Postflow
10s
0 - 30s (step 1s)
Current
selected value
(s)
Stick Welding: SOFT and CRISP programs
Parameter Features
Selectable Value Range
Displayed
parameter
name
Displayed
value
Soft Stick
Hot start, Anti-Sticking and Arc Force are
automatically adjusted by the machine
Set Current
With SOFT / CRISP Stick,
this is the unique parameter
adjustable by the user.
Current
selected value
(A)
Crisp Stick
Hot start, Anti-Sticking and Arc Force are
automatically adjusted by the machine
Current
selected value
(A)
TIG SPOT WELDING (to previously enable with option 10 in Setup menu)
Parameter Features
Selectable Value Range
Displayed
parameter
name
Displayed
value
Spot Current
Trigger = 2-step
No restart function enabled
Preflow time = 0s
Upslope time = 0s
Downslope time = 0s
Postflow time = 0s
5 - 300A (300TPX)
5 - 400A (400TPX)
Voltage at
output studs
Current
selected value
(A)