English 9 English 

the knob 30, the time is set up in seconds either to reach 
the final current welding in the Four Times mode, or to 
cancel the nominal current welding in the Two Times 
mode. 
The frequency can be regulated between the following 
ranges: 

  Between 0,3 Hz and 1Hz with a 0,1 Hz step. 

  Between 1 Hz and 250Hz with a 1 Hz step. 

 

 

 
 

Descent Slope 

By pressing function keys 31 e 32 the luminous indicator 
is position at 27 - Picture 1 Page 6.); then by activating 
the knob 30, the time is set up in seconds either to reach 
the final current welding in the Four Times mode, or to 
cancel the nominal current welding in the Two Times 
mode. 
The value range is between 0 and 10 seconds. 
 

 

 
 

Final Current 

By pressing function keys 31 e 32 the luminous indicator 
is position at 28 - Picture 1 Page 6.); then by activating 
the knob 30, the value for the final current on the TIG 
Four Times mode is set up. The value range is between 
I Min and the nominal current welding. 
 

 

 
 

Post gas 

By pressing function keys 31 e 32 32 the luminous 
indicator is position at 29 - Picture 1 Page 6.) then by 
activating the knob 30, the time length for the final gas 
flux is set up in seconds. The value range is between 0,2 
and 20 seconds. 
 

 

 
 

Four times functionality for TIG welding 

 
The generator allows a management of the Four Times 
Intelligent mode. In fact, it is possible to modify the 
automatic sequence depending on how the torch button 
is used (See picture). 
The current's descent slope is also possible from the 
reduced current. 
 
 
Pressure without the torch button release. 
 
 
 
Torch button release. 
 
 
 
Pressure and immediate release of the torch 
button. 
 
 
Release and immediate pressure of the torch 
button. 

27 

28 

29 

   

26 

Содержание INVERTEC 175TP

Страница 1: ...800036917 05 2019 REV02 INVERTEC 175TP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Страница 2: ...r future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where P...

Страница 3: ...A Maximum consumption 21 A 14 A SECONDARY SIDE Open circuit voltage 50 V Peak voltage 10kV Welding current 5 A 175 A Duty cycle 25 175 A Duty cycle 60 140 A Duty cycle 100 120 A 130 A MISCELLEANOUS P...

Страница 4: ...ontrol equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating...

Страница 5: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Страница 6: ...y be subjected to physical damage or the welding process including sparks and heat sources HF CAUTION The high frequency used for contact free ignition with TIG GTAW welding can interfere with the ope...

Страница 7: ...BEFORE INSERTING THE MAINS PLUG IN ORDER TO AVOID THE FAIL OF POWER SOURCE CHECK IF THE MAINS CORRESPONDS TO THE WISHED MAIN SUPPLY On off switch This switch has two positions ON I and OFF O THIS CLAS...

Страница 8: ...minous indicator reaches the position on symbol 2 Picture 1 Page 6 If you press the torch button you will get a high voltage discharge that allows the arc fusing TIG DC Welding with Lift Start By pres...

Страница 9: ...circuit Output stage failure Eliminate the short circuit Call after sales service PiF The inverter stage does not work properly NOTE whenever all the panel luminous indicators remain on or off simulta...

Страница 10: ...wo or Four Times the pulsation of the basic current is set up The value range is between the nominal current welding and the 10 of that same value Spot Time By pressing function keys 31 e 32 the lumin...

Страница 11: ...inous indicator is position at 28 Picture 1 Page 6 then by activating the knob 30 the value for the final current on the TIG Four Times mode is set up The value range is between I Min and the nominal...

Страница 12: ...for more than three seconds the key 31 At this point desired program is loaded the recall is accompanied by long beep The exit from this state is possible in three ways 1 Recalling a program 2 Inactiv...

Страница 13: ...G WELDING FAULTS POSSIBLE CAUSES CONTROLS AND REMEDIES The generator does not weld the digital switch is not lit The main switch is off The power lead is interrupted lack of one or two phases Other Sw...

Страница 14: ...ny is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purcha...

Страница 15: ...he Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine...

Отзывы: