A-1

INSTALLATION   

IDEALARC® AC-1200

A-1

LOCATION

Install the welder in a dry location where there is free circu-
lation of air in through the louvers in front and out through
the louvers in the back of the case. A location which mini-
mizes  the  amount  of  smoke  and  dirt  drawn  into the
machine reduces the chance of dirt accumulation that can
block air passages and cause overheating.

INPuT WIRING

Failure to fuse the input lines per the specifications
in this manual will constitute customer abuse and
void the warranty.

---------------------------------------------------------------

Have a qualified electrician make the complete input con-
nection  in  accordance  with  the  National  Electrical  Code,
all local codes and the connection diagram located inside
the machine.

Be sure the voltage, phase and frequency of the input power
is as specified on the welder nameplate.

For most installations, connect the AC-1200 to single phase
power or to one phase of a three phase line. Unbalanced
line conditions can be easily avoided by properly balancing
the AC-1200 with other machinery on the lines.

When  installing  two  or  four  Scott  connected  AC-1200
machines for AC-AC tandem arc welding, three phase input
power must be used. The terminals for connections to pro-
vide an output phase angle less than or greater than the
usual 90%  phase angle are included on the input panel.

The AC-1200 does not have an input contactor. Therefore,
include an external starter or disconnect switch when plan-
ning the input circuit.
Remove the right side panel of teh AC-1200 and bring the input
power  lines  through  the  hole  in  the  back  of  the  case.  See  the
table  below  for  reccomended  sizing  of  input leads  and  overcur-
rent protection.

The frame of the welder must be grounded, A stud marked with
the symbol             located on the welder case back hole in the
back of the case is provided for this purpose. See the National
Electrical Code for details on proper grounding methods.

OuTPuT CONNECTIONS

a. Wire Feeder Connection

Turn  the  input  power  to  the  welder  off.  Remove  the  screw
and  lift  the  hinged  door  on  the  front  of  the  control panel  to
expose  the  terminal  strips.  Connect  the  leads  of  the  wire
feeder  input  control  cable  to  the  terminal  strips  exactly  as
specified in the appropriate connection diagram. The AC-1200
to  NA-4  connection  diagrams  are  included  in  the  NA-4
Operating  Manual  IM-278.  Attach  the  control  cables  to  the
panel at the right of the terminal strip using the clamps pro-
vided.

If  connecting  the  AC-1200  to  an  older  NA-4  with  the  toggle
switch  type  ‘Current  Control’  (below  code  7532), a  K-775
‘Remote  Control’  must  be  purchased  and  instal-led  in  accor-
dance  with  the  connection  diagram  S-15667 on page 5. The
‘Remote Control’ cord can be lengthened to any length by prop-
erly  splicing  a  four  conductor  cord to  the  standard  25’  cord
before connecting to the AC-1200 terminal strip.

If connecting the AC-1200 to an LAF-4 or the AC controls of
the  LT-34  tractor,  the  AC-1200  must  be  ordered with  the
required ‘–NL’ optional circuit installed. This kit includes the
K-775  ‘Remote  Control’.  Connect  in  accordance  with  dia-
gram S-15666 on page 5.

To connect the AC-1200 to any other wire feeder, write to the
factory  for  instructions  giving  complete  nameplate information
for the specific equipment.

When connection to the terminal strips are completed, close
the door and replace the screw.

RATING: IP21 ENCLOSURE,  INSULATION 155(F)

Thomas & Betts wire terminals (or equal) recommended above are required to comply with applicable U.L. stan-
dards for safety. A #30 hex (Allen) key wrench is required for assembly of terminals to wire.

Recommended Input Wire, Grounding Conductor and Fuse Sizes

Based on National Electrical Code - 100% Duty Cycle 40˚C (104˚F) Ambient

Copper Wire Size - 75˚C in Conduit

Super Lag Fuses

Input Amps

Power Input Wires

Grounding Conductor

Size in Amps

Input

Voltage/ 1 Phase Scott 1 Phase T & B

Scott

T & B 1 Phase T & B Scott T & B 1 Phase Scott

Hertz

Conn.

Term.

Conn.

Term.

Term. Conn. Term.

Conn.

460/60

182

209

#4/0

31013

250MCM 31013

#4

31007

#3

31007

300

350

440/50/60

190

219

#4/0

31013

250MCM 31013

#4

31007

#3

31007

300

350

380/50/60

230

254

250MCM 31013

350MCM 31015

#3

31007

#3

31007

300

400

WARNING

ELECTRIC SHOCK

can kill.

• Have an electrician install and

service this equipment.

• Turn the input power off at the

fuse box before working on
equipment.

• Do not touch electrically hot

parts.

Содержание IDEALARC AC-1200

Страница 1: ...T WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CON TAINED THROUGHOUT And most importantly think before you act and be careful For use with machines having Code Numbers 10291C 10292C 10465 an...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders 3 i When w...

Страница 4: ...eas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to prevent hazardous situ...

Страница 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Страница 6: ...mportant when identifying the correct replacement parts On Line Product Registration Register your machine with Lincoln Electric either via fax or over the Internet For faxing Complete the form on the...

Страница 7: ...utions B 1 To set for machine or Remote Control B 1 To set Output Current B 1 ________________________________________________________________________________ Maintenance Section D Safety Precautions...

Страница 8: ...xpose the terminal strips Connect the leads of the wire feeder input control cable to the terminal strips exactly as specified in the appropriate connection diagram The AC 1200 to NA 4 connection diag...

Страница 9: ...Connection of AC 1200 with NL Option S 15666 to LAF 4 or LT 34 4 18 75 Connection of AC 1200 to NA 4 S 15667 with Switch for Current Control 4 18 75 Connection of AC 1200 to NA 4 with rheostat for cur...

Страница 10: ...nuts with a wrench Select cables required for combined work and electrode cable lengths up to 150 from the following table Maximum Allowable Current for Copper Welding Cable Cables in accessory kit re...

Страница 11: ...D WITH MANUAL ELECTRODES Turn the welder off disconnect the wire feeder leads and connect a jumper between 2 and 4 on the AC 1200 terminal strip This closes the output con tactors making the output st...

Страница 12: ...ch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground Always wear dry insulating gloves See additional warning information throughout this operator s...

Страница 13: ...BLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause general...

Страница 14: ...across 31 and 32 Remote control switch in wrong posi tion Control rheostat open Control circuit open Open saturable reactor control coil or connection Look for possible cause and repair Replace fuse R...

Страница 15: ...URSE OF ACTION Welder welds at max only no con trol Contacts chatter Diodes or SCR s on heat sink assemblies shorted Shorted or grounded current controll rheostat Output By Pass Capacitors open or dis...

Страница 16: ...It may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write...

Страница 17: ...Do not operate with covers removed Do not touch electrically live parts Only qualified persons should install use or service this equipment B M13026 N C PRIMARY SEC ELEC WORK 1 7 8 9 10 4 N D N E N C...

Страница 18: ...F 3 DIAGRAMS F 3 IDEALARC AC 1200 AC 1200 SCOTT CONNECTION DIAGRAM...

Страница 19: ...F 4 DIAGRAMS F 4 IDEALARC AC 1200 AC 1200 AND PARALLELED DC 1000 s...

Страница 20: ...F 5 DIAGRAMS F 5 IDEALARC AC 1200 AC 1200 AND DC 1500 s...

Страница 21: ...is for reference only It is not accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram i...

Страница 22: ...NOTES IDEALARC AC 1200...

Страница 23: ...NOTES IDEALARC AC 1200...

Страница 24: ...NOTES IDEALARC AC 1200...

Страница 25: ...h electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 26: ...te Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentac...

Страница 27: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: