8695 4985 / C
F - MAINTENANCE
ESSENTIAL OXYCUTTING
F-27
2 - TROUBLESHOOTING
2.1 Electrical problems
Reminder: all work is to be carried out by approved and trained
personnel
If any fault occurs in the oxycutting equipment due to an electrical problem, first check the fuses. Before opening
the manifold box, switch the machine off. Using the emergency stop does not mean that there is no voltage in the
box.
The fuses «
E1
» :
F14 and F15 power the motors of the tool holders (Description n : FUSE 5X20 5A 250V FSF)
(F10 to F16) switch off the 24V power to the rest of the process. (Description : FUSE 5X20 5A 250V FSF)
While troubleshooting, the Air Liquide technician may ask you to check the status of the indicators inputs/outputs
«
E2
», and also those on each of the solenoid valves, which have an indicator that goes on when the valve supply
is on.
On the PLC, faulty inputs/outputs are red.