8695 4985 / C
ESSENTIAL OXYCUTTING
F-25
F - MAINTENANCE
1 - SERVICING
So that the machine continues to provide good service for as long as possible, a certain minimum of care and
maintenance is necessary
The frequency of this maintenance work is given on the basis of the production of one work station per day.
Maintenance should be more frequent if production is greater.
Your maintenance department may photocopy these pages so that it can follow up maintenance dates and
operations (tick as appropriate)
Weekly
Date of maintenance : / /
General machine cleaning in order to eliminate oxycutting dust
When cleaning the
HPC
screen:
- switch off the numerical control
- use soapy water and a lint-free cloth
- never use solvents or grinding materials
Monthly
Date of maintenance : / /
- Check that the gas circuit operates properly: pressure gauge, pressure regulator,
electrovalve, valve, couplings, etc.
Note : any piping showing the slightest signs of fatigue, wear, damage, should be replaced
by a standard identical pipe.
- Check the condition of all the electrical cables, especially near the torches and in the cable
support chain (change them if required). Check that electrical wires are tightened.
FILTRE CIRCUIT GAZ
Dust in the filters reduce the available output and can lead to explosions.
Clean the filter with non-greasy degreasing agent
.
Read the safety data sheet carefully and
take all the steps indicated Dry well afterwards.
Before reassembly, apply either
“1000 bulles” leak detector or soapy water on the plug
thread.
Never use a greasy substance (such as oil or grease).
Содержание ESSENTIAL OXYCUTTING
Страница 6: ...A IDENTIFICATION 8695 4985 C A 2 ESSENTIAL OXYCUTTING ...
Страница 12: ...B SAFETY INSTRUCTIONS 8695 4985 C B 8 ESSENTIAL OXYCUTTING ...
Страница 20: ...C DESCRIPTION 8695 4985 C C 16 ESSENTIAL OXYCUTTING ...
Страница 24: ...D MONTAGE INSTALLATION 8695 4985 C D 20 ESSENTIAL OXYCUTTING ...
Страница 28: ...E OPERATOR MANUAL 8695 4985 D E 24 ESSENTIAL OXYCUTTING ...
Страница 38: ...F MAINTENANCE 8695 4985 C F 34 ESSENTIAL OXYCUTTING 3 2 Process and tool holder control system in main cabinet ...