B-13
OPERATION
DUAL MAVERICK
®
450
SET-UP
The set-up allows for customization of the Maverick. Options
available in the Set-up menu are:
•
AUTO-START: NO LOAD PERIOD
•
TAP START ACTIVE PERIOD
•
AUTO-START: ON/OFF
•
PIN
•
DISPLAY BRIGHTNESS
•
DIAGNOSTIC INFORMATION
- Diagnostic information page
can be used to get useful information about the welder. ECG
FAULT CODE is the number of pulse detected from ECG fault
lamp. The fault codes can be found in troubleshooting section
(E-4).
•
NEW PCB CALIBRATION
- When new PCB(s) is installed on
the machine, calibration is needed for both Single and Dual
modes. On Single mode, only follow the instructions on the
left display. On Dual mode, only follow the instructions on the
right display. To ensure proper calibration ensure mode was
in Stick at 150 amps set point before entering setup menu.
Failure to do so will not allow welder to enter calibration
mode.
•
VARIABLE SPEED ON/OFF
- Turn the variable speed function
off when desired weld output is not reached. For example, in
high altitude areas that have lower oxygen levels, the
operator can turn off the variable speed function to increase
weld output.
•
RESTORE FACTORY SETTINGS
•
MACHINE SELECT
- When a new PCB(s) is installed on the
machine, the PCB has to go through a "Machine Select"
process. This setup option should only be used if the initial
"Machine Select" process was not completed successfully.
To enter this setup option use the following pass code: 3210.
Ensure the correct K # and Code number is used for the
machine. Failure to do so can permanently damage the
welder.
?
Press knob to select
Set-up
?
Press knob to select
Auto-Start: No Load Period
Tap Start Active Period
Auto-Start: On/Off
PIN
Display Brightness
Diagnostic information