A-9
INSTALLATION
DOWNFLEX 200/400
A-9
• Position the downdraft table against the wall.
• If necessary, use the adjusting feet to level the down-
draft table and to adjust it to the desired height (min.
36 in. - max. 38 in. 920-970 mm). See Figure A.15.
ELECTRIC CONNECTION
If necessary: change motor from 480V to 208/240V
Default setting of the motor is 480V. Depending on the
local input power voltage, the setting could be changed
to 208/240V. This concerns both the motor and the
transformer.
Do not position the product where it is exposed to
vibrations or heat radiation from heat sources.
Observe the earlier described ambient conditions.
------------------------------------------------------------------------
CAUTION
FIGURE A.14 – CARGO LASHINGS
FIGURE A.15 – ADJUSTABLE FEET
50
mm
• Lift only with equipment of
adequate lifting capacity.
• Be sure machine is stable
when lifting.
• Do not lift this machine using
lift bail if it is equipped with a
heavy accessory such as trail-
er or gas cylinder.
FALLING
• Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bail.
------------------------------------------------------------------------
WARNING
Make sure that the system is suitable for connec-
tion to the local input power. Information about the
connection voltage and frequency can be found on
the identification plate.
The input power must be connected in confor-
mance with the local codes and regulations and
can only be installed by well qualified and autho-
rized technicians.
------------------------------------------------------------------------
CAUTION
Make sure the downdraft table is
disconnected from input power.
------------------------------------------------------------------------
WARNING