A-11
INSTALLATION
DOWNFLEX 200/400
A-11
The downdraft table can by connected to input power
by:
• 3ph plug (grounded); or
• Directly to the power supply
1. Connect the main cord (A) to the input power. See
Figure A.18.
The supply cable for the power outlet can be connect-
ed to input power by:
• A 1ph plug (grounded); or
• Directly to the power supply
1. Connect the supply cable (B) to the input power.
See Figure A.18.
DIRECTION OF ROTATION
Check the direction of rotation of the fan.
1. Turn on the main switch.
2. Push the ON button to switch on the fan.
3. Push the OFF button to switch off the fan.
4. Wait 20 seconds.
5. Open the left door.
The motor contains a sticker indicating the correct
direction of rotation.
1. Check the direction of rotation during the slow-
down period of the fan.
2. Turn off the main switch.
3. Disconnect the downdraft table from the input
power.
4. If the fan is rotating in the wrong direction change
the connection of the phases.
Be sure to mount the right fuse
type.
Plugs/connections to be installed in
accordance with the National
Electrical Code (NEC) and local
requirements.
------------------------------------------------------------------------
WARNING
Do not open the door within 20 sec-
onds after switching off the fan.
Keep your hands away from the fan
wheel.
------------------------------------------------------------------------
WARNING
FIGURE A.18 – ELECTRIC CONNECTION
B
A
Содержание DOWNFLEX 200