Lincoln Electric CV320-I Скачать руководство пользователя страница 6

•  Turn the input  power off at the

disconnect switch before installing
or servicing this machine.

•  Do not touch electrically “hot” parts

such as output terminals or internal
wiring.

•  Connect grounding screw (   ) to a

good earth ground.

•  Do not operate with covers removed.

•  Turn power switch “off” before

connecting or disconnecting cables
or other equipment.

WARNING

HIGH

VOLTAGE

can kill

Page  6

CV320-I

IMA 574B

PRODUCT DESCRIPTION

The CV320-I is a semi-automatic Constant Voltage DC arc welding power source and wire feeder. It combines a step controlled power
source with a separate solid state controlled wire feeder.

Excellent arc characteristics are provided for both gas shielded and self shielded welding within its current range.

For instructions on operation of the wire feeder refer to the separate instruction manual included. Standard features include output volt &
amp meters, a spot timer, gas purge facilities, a dual position 2 or 4 step trigger interlock, a Magnum FM400 gun, a regulator/flowmeter
and gas hose, a 10m electrode cable and wire feeder cable, a 3m ground cable assembly, a 3m long input lead and an undercarriage on
which a gas cylinder can be mounted.

Only qualified personnel should install or service this
equipment.

Location

Place the welder where clean cooling air can freely circulate in
through the intake louvers and out through the exhaust louvers.
Dirt, dust or any foreign material that can be drawn into the welder
should be kept at a minimum. Failure to observe these
precautions can result in excessive operating temperatures and
nuisance thermostat trips.

Wire Feeder Mounting

Locate the control cable at the rear of the CV320-I and plug into
the wire feeder. The control cable is already connected to the
CV320-I. Connect the supplied 1.5m electrode cable to the wire
feeder mechconnector and to the desired polarity terminal on the
front of the CV320-I.

Connection to Mains Supply

Before connecting the machine to the mains supply check that the
voltage and current capacity correspond to the machine voltage
and rated input current. Use a fuse or C/B per AS3000 or local
wiring rules.

The machine is supplied with an input lead fitted. Have a qualified
electrician fit a suitable input plug.

Once the above has been followed the machine can be plugged
into the mains outlet.

Shielding Gas Supply
(For the Gas Metal Arc Welding Process)

Refer “Safety in Welding and Cutting” - ANSI Standard Z49.1 and
WTIA Technical Note 7, available from the Welding Technology
Institute of Australia.

Obtain cylinder of appropriate type shielding gas for the process
being used.

1.

Set gas cylinder on rear platform of the machine. Hook chain
in place to secure cylinder to rear of welder.

2.

Remove the cylinder cap. Inspect the cylinder valve for
damaged threads, dirt and dust. For cylinders having an
external thread fitting, remove any dust and dirt from the
threads with a clean cloth.

CYLINDER may explode
if damaged

Part No.

KA 1392 & KA1392-1

Maximum Open Circuit Voltage

45V

Output Current Range

20 to 400A

Duty Cycle

30%

60%

100%

Rated Output 

320A/30V

240A/26V

190A/23.5V

Rated Input

KA1392 415V 3ph 50Hz 13.5 amps

KA1392-1 380V 3ph 50hz 14.7amps

Wire Speed Range

1-20 m/min

Weight (complete with u/c)

140 kg

H x W x L (mm) Over wire feeder,

cylinder tray & wheels

1220 x 580 x 842 mm

Operating Temperature

-20˚C to 40˚C

Specifications

INSTALLATION

Never connect the green/yellow conductor to any of the
three active supply lines from the mains. This conductor is
to earth the machine as required by Electrical Regulations.

CAUTION

Содержание CV320-I

Страница 1: ...n mind However your overall safety can be increased by proper installation and thoughtful operation on your part Read and observe the general safety precautions on page 2 and follow specific installat...

Страница 2: ...erstand the manufacturer s instructions for this equipment and the consumables to be used including the material safety data sheet MSDS and follow your employer s safety practices e Also see Item 7b 3...

Страница 3: ...cessary to remove safety guards to perform required maintenance Remove guards only when necessary and replace them when the maintenance requiring their removal is complete Always use the greatest care...

Страница 4: ...makers function Generally the interference does not permanently damage the pacemaker Once the wearer leaves the arc welding environment or stops welding the pacemaker returns to normal functioning The...

Страница 5: ...easures h The time of the day that welding or other activities are to be carried out The size of the surrounding area to be considered will depend on the structure of the building and other activities...

Страница 6: ...to the wire feeder The control cable is already connected to the CV320 I Connect the supplied 1 5m electrode cable to the wire feeder mechconnector and to the desired polarity terminal on the front of...

Страница 7: ...aligned with the proper mating sockets on the front panel gun connector and then join the connectors and tighten the hand nut on the gun cable connector NOTE If a gun and cable other than the Magnum F...

Страница 8: ...nt control as the power source will deliver the current necessary to melt the wire The higher the speed the more current will be required Over temperature light Indicates that the thermostats have ope...

Страница 9: ...erature because of a frequent overload or high ambient temperature plus overload The over temperature light glows when the thermostats open The thermostats automatically reset when the temperature rea...

Страница 10: ...gun cable and replace if necessary Remove wire from gun and cable feed in new wire Note any obstructions in gun and cable Replace gun and cable if necessary See Wire Drive Roll Section in this manual...

Страница 11: ...ny modifications could have taken place over the life of a particular machine so details of this procedure may need to be adjusted to suit these modifications For prompt service contact your local Lin...

Страница 12: ...S4449 2 AM3023E 0 9 1 2mm AS4449 8 Cored Wire 0 8 1 0mm AS4449 3 1 2 1 6mm AS4449 4 AM3023J Aluminium Wire 0 8 1 0mm AS4449 5 1 0 1 2mm AM3023F 1 2 1 6mm AS4449 6 AM3023K DRIVE ROLLS Note LN 21 Code N...

Страница 13: ...AL2513 IMA574A 415V 1509 KA1392 1 1 AL2513 IMA574B 380V 1510 KA1392 1 2 1 AL2513 IMA574B 415V 1535 KA1392 1 1 AL2513 IMA574B LN 21 1413 KA1389 AP 68 N A AM3392 IMA565A 1508 KA1389 AP 68 N A AM3392 IM...

Страница 14: ...20 I IMA 574B General Assembly AP 80 C Roof and side panels not shown for clarity Platform shown this view only Front panel not shown for clarity Ref AG1369 A15 5 96M AP 80 C Operative 2 7 99 Superced...

Страница 15: ...4 X X 5 16 UNC Hex Nut 4 X X 5 16 dia Flatwasher 4 X X 5 16 dia Springwasher 4 X X 68 Plastic Bag 9 x 12 1 X X 69 Staple 3 X X 70 KA1389 LN21 1 X X 71 Plastic Bag 1 X X 72 Pallet 1 X X Item Part No De...

Страница 16: ...9 T3960 Flange Nut 2 X 10 AS1733 3Z Self Tapping Screw 4 X 11 AS4460 Indicator Light 1 X 12 T13486 1 Pilot Light 1 X 13 S6602 22 Shunt 1 X 15 Lead 48 1 X 16 AM3400 Meter Lead Harness 1 X A1 AM3388 2 O...

Страница 17: ...hine s wiring For specific detail refer to the diagram attached to the machine itself If the diagram has been destroyed or defaced contact the factory quoting the machine serial number and code number...

Страница 18: ...Department for any code numbers not listed Numbers in the table below indicate which column to use in each parts list for each individual code number Sub Assembly Item No 1 2 3 Sub Assembly Page Name...

Страница 19: ...E 4 1 AM3382 2 NAMEPLATE LN21 1 AM3382 3 x 11 FASTENER BUTTON 2 TI4659 1 x 11A FASTENER BUTTON 1 T14659 x 12 GUN ADAPTOR 1 AS4456 x x 13 HEX HD SCREW 3 x SPRINGWASHER 3 x FLATWASHER 3 x HEX NUT 3 x 13...

Страница 20: ...UST STRIP RETAINING PLATE 1 AS4452 x x 45 SELF TAPPING SCREW 2 AS1733 3Z x x 46 WARNING DECAL 1 AS4244 x x 47 CODE AND SERIAL No DECAL 1 x x 49 SPACERS 2 AS4463 x 50 SLEEVING over motor leads 1 AM3058...

Страница 21: ...chine s wiring For specific detail refer to the diagram attached to the machine itself If the diagram has been destroyed or defaced contact the factory quoting the machine serial number and code numbe...

Страница 22: ...Magnum 200FM 12 7 mm ID M16082 2 Magnum 400FM 12 7 mm ID 2 Gas nozzle Recessed slip on requires Item 2A M16082 3 Magnum 400FM 15 9 mm ID M16082 4 Magnum 400FM 12 7 mm ID Item Part No Description 2A N...

Страница 23: ...using left Magnum 200FM G2091 Gun housing right Magnum 200FM 16 S18825 1 6 x 32 screw 17 T14438 Clamping screw 18 S18932 Trigger assembly 19 T13483 8 O ring 20 S18655 1 Connector assembly Magnum 400FM...

Страница 24: ...2 7 0 50 M16082 4M 25 M16082 3 1 24A 62 SS M16082 3D 5 15 9 0 62 M16082 3M 25 Industry Lincoln ID Ref No Part No Qty mm Inches 24CT 62 R M16830 3 1 15 9 0 62 M16830 3M 25 24CT 62 S M16830 1 1 15 9 0 6...

Страница 25: ...1 2 0 045 14T 23 S19393 5D 10 S19393 5M 25 0 6 0 025 14T 30 S19393 6D 10 S19393 6M 25 0 8 0 030 14T 35 S19393 1D 10 S19393 1M 25 0 9 0 035 14T 40 S19393 7D 10 S19393 7M 25 1 0 0 040 14T 45 S19393 2D 1...

Страница 26: ...sories warranty service can only be carried out by authorised Lincoln Field Service Shop or the engine distributors authorised by the Lincoln branch office iii Intermotor Engines and Accessories 12 mo...

Отзывы: