background image

SECTION A:

WARNINGS

  

CALIFORNIA PROPOSITION 65 WARNINGS

WARNING: 

Breathing diesel engine exhaust

exposes you to chemicals known to the State

of California to cause cancer and birth defects,

or other reproductive harm.

• Always start and operate the engine in a

well-ventilated area.

• If in an exposed area, vent the exhaust to the outside.
• Do not modify or tamper with the exhaust system.
• Do not idle the engine except as necessary.

For more information go to 

www.P65 warnings.ca.gov/diesel

WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 

et seq.)

WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov

ARC WELDING CAN BE HAZARDOUS. PROTECT

YOURSELF AND OTHERS FROM POSSIBLE SERIOUS

INJURY OR DEATH. KEEP CHILDREN AWAY. 

PACEMAKER WEARERS SHOULD CONSULT WITH

THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For

additional safety information, it is strongly recommended 

that you purchase a copy of “Safety in Welding & Cutting - 

ANSI Standard Z49.1” from the American Welding Society, 

P.O. Box 351040, Miami, Florida 33135 or CSA Standard 

W117.2. A Free copy of “Arc Welding Safety” booklet E205 

is available from the Lincoln Electric Company, 22801

St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION,

MAINTENANCE AND REPAIR PROCEDURES ARE

PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE POWERED

EQUIPMENT.

1.a. Turn the engine off before troubleshooting

and maintenance work unless the
maintenance work requires it to be running.

1.b. Operate engines in open, well-ventilated areas or vent the engine

exhaust fumes outdoors.

arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact

tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.

1.d.  Keep all equipment safety guards, covers

and devices in position and in good repair.
Keep hands, hair, clothing and tools away 
from V-belts, gears, fans and all other 
moving parts when starting, operating or
repairing equipment.

1.e. In some cases it may be necessary to remove safety guards to

perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.

1.f.  Do not put your hands near the engine fan. Do not attempt to

override the governor or idler by pushing on the throttle control
rods while the engine is running.

1.g. To prevent accidentally starting gasoline engines while turning

the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or  magneto wire
as appropriate.

1.h. To avoid scalding, do not remove the radiator

pressure cap when the engine is 

hot.

ELECTRIC AND

MAGNETIC FIELDS MAY

BE DANGEROUS

causes localized Electric and Magnetic Fields (EMF). 

and welding machines

welders having a pacemaker should consult their physician
before welding.

which are now not known.

2.d. All welders should use the following procedures in order to

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work

cables. If the electrode cable is on your right side, the
work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as pos-

sible to the area being welded.

2.d.5. Do not work next to welding power source.

SAFETY

Safety 02 of 04 - 10/08/2021

1.c. Do not add the fuel near an open flame welding

with hot engine parts and igniting. Do not spill fuel when filling

2.a. Electric current flowing through any conductor

Welding current creates EMF fields around welding cables

2.b. EMF fields may interfere with some pacemakers, and

2.c. Exposure to EMF fields in welding may have other health effects

minimize exposure to EMF fields from the welding circuit:

1.i. Using a generator indoors CAN KILL YOU IN

MINUTES.

1.j. Generator exhaust contains carbon monoxide. This is a poison

you cannot see or smell.

1.k.  NEVER use inside a home or garage,

EVEN IF doors and windows are open.

1.l.   Only use OUTSIDE and far away from

windows, doors and vents.

1.m. Avoid other generator hazards. READ

MANUAL BEFORE USE.

Содержание CALIBER K4841-17

Страница 1: ...842 26 K4842 26F K4842 26FV Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overall safety can be increased by proper installation and thought ful operation on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MAN UAL AND THE SAFETY PRE CAUTIONS CONTAINED THROUGHOUT And most importantly think before...

Страница 2: ...N A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual symptoms see your supervisor Perhaps the welding atmosphere and ventilation system should be checked WEAR CORRECT EYE EAR BODY PROTECTION PROTECT your eyes and face with welding helmet properly fitted...

Страница 3: ... belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some cases it may be necessary to remove safety guards to perform required maintenance Remove guards only when necessary and replace them when the maintenance requiring their removal is complete Always use the greatest care when working near moving parts 1 f Do not put your hands near the engine fan ...

Страница 4: ...m to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with suitable non flammable screening and or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal FUMES AND GASES CAN BE DANGEROUS 5 a Welding may produce fumes an...

Страница 5: ...ent passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow NFPA 51B Standard for Fire Prevention During Welding Cutting and Other Hot Work available from NFPA 1 Batterymarch Park PO box 9101 Quincy MA 022690 9101 6 j Do not use a welding power source for pipe...

Страница 6: ...try Reference VS 2 41V24 41V35 41V33 598882 Rigid torch body Flex torch body Flex valve torch body Valve knob with O ring Torch handle Power cable with gas 12 1 2 3 8m Power cable with gas 25 7 6m Back cap long with O ring 2 pack Back cap medium with O ring 2 pack Back cap short with O ring 2 pack Standard insulator 2 pack Insulator Collet Collet body Alumina nozzle Collet body gas lens Descriptio...

Страница 7: ...25 40 10 20 20 30 30 80 60 130 100 180 5 20 20 60 60 120 100 180 160 250 5 15 10 60 50 100 100 160 150 210 5 20 15 80 70 150 140 235 225 325 4 5 6 4 5 6 5 6 6 7 8 6 7 8 1 With argon gas 2 DCEP is not commonly used in these sizes Tungsten Electrode Diameter in mm Collet Part No Industry Ref Collet Body Part No Industry Ref Gas Lens Collet Body Part No Industry Ref 0 020 0 5 0 040 1 0 1 16 1 6 3 32 ...

Страница 8: ...stry Reference VS 2 57Y02 57Y03 57Y04 18CG 54N01 Rigid torch body Flex torch body Flex valve torch body Valve knob with O ring Torch handle Power cable and gas 12 1 2 3 8m Power cable and gas 25 7 6m Back cap long with O ring 2 pack Back cap medium with O ring 2 pack Back cap short with O ring 2 pack Standard insulator 2 pack Insulator Collet Collet body Alumina nozzle Gas lens insulator 2 pack Co...

Страница 9: ...S FOR TUNGSTEN ELECTRODES 1 Tungsten Electrode Diameter in mm Pure and 1 2 Thoriated Tungsten Pure and 1 2 Thoriated Tungsten DCEN DCEP Pure Tungsten 1 2 Thoriated Tungsten Zirconiated Pure Tungsten Balanced Wave AC Unbalanced Wave 1 2 Thoriated Tungsten Zirconiated Alumina Nozzle Size 0 020 0 5 0 040 1 0 1 16 1 6 3 32 2 4 1 8 3 2 5 32 4 0 5 20 15 80 70 150 150 250 250 400 400 500 2 2 10 20 15 30 ...

Страница 10: ...ry Reference VS 1 57Y02 57Y03 57Y04 18CG 54N01 Rigid torch body Flex torch body Flex valve torch body Valve knob with O ring Torch handle Power cable with gas 12 1 2 3 8m Power cable with gas 25 7 6m Back cap long with O ring 2 pack Back cap medium with O ring 2 pack Back cap short with O ring 2 pack Standard insulator 2 pack Insulator Collet Collet body Alumina nozzle Gas lens insulator 2 pack Co...

Страница 11: ...NGES FOR TUNGSTEN ELECTRODES 1 Tungsten Electrode Diameter in mm Pure and 1 2 Thoriated Tungsten Pure and 1 2 Thoriated Tungsten DCEN DCEP Pure Tungsten 1 2 Thoriated Tungsten Zirconiated Pure Tungsten Balanced Wave AC Unbalanced Wave 1 2 Thoriated Tungsten Zirconiated Alumina Nozzle Size 0 020 0 5 0 040 1 0 1 16 1 6 3 32 2 4 1 8 3 2 5 32 4 0 5 20 15 80 70 150 150 250 250 400 400 500 2 2 10 20 15 ...

Страница 12: ...CONNECTION DIAGRAMS POWER SOURCE GAS SOLENOID 1 PIECE POWER CABLE TORCH GAS VALVE 1 PIECE POWER CABLE Note Refer to the manufacturer s power source operating manual for recommended installation practice ...

Страница 13: ...parately Quantity KP505 For K4844 9F K4841 17F K4842 26F Part No Industry Ref Description 1 1 S19558 1 40V77 S19558 2 Gas hose 12 1 2 3 8mm Gas hose 18 457mm from solenoid valve to power cable adapter Order correct power cable adapter Quantity KP506 For K4844 9FV K4841 17FV K4842 26FV Part No Description 1 S19558 1 Gas hose 12 1 2 3 8mm with 5 8 18 right Order necessary power cable adapter for 1 p...

Страница 14: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y de la tierra Ne laissez ni la peau ni des vête ments mouillés entrer en contact avec des pièces sous tension Isolez vous du travail et de la terre Berühren Sie keine stromführenden Teile oder Elektrode...

Страница 15: ...gute Be und Entlüftung des Arbeitsplatzes Mantenha seu rosto da fumaça Use ventilação e exhaustão para remover fumo da zona respiratória Turn power off before servicing Desconectar el cable de ali mentación de poder de la máquina antes de iniciar cualquier servicio Débranchez le courant avant l entre tien Strom vor Wartungsarbeiten abschalten Netzstrom völlig öff nen Maschine anhalten Não opere co...

Страница 16: ...s and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Products ...

Отзывы: