![Lincoln Electric 95032111NG Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/lincoln-electric/95032111ng/95032111ng_safety-instruction-for-use-and-maintenance_1918179021.webp)
8695 6645 / C
D - ASSEMBLY - INSTALLATION
POSIMATIC PS08
D-17
5 - INSTALLATION
a) Checking after transport
The positioner is delivered ready for operation.
However, certain preliminary steps should be taken before starting-up:
- make sure that no visible element has been damaged during transport,
- check that the main elements are properly tightened; transport may have loosened them, especially
tilt limit switches,
- check that electrical connections are correct.
b) Checking phase direction
- check that the electrical connections are correct,
- press the plate lowering button «
C5
»
the plate lowers: the phases are connected properly
the plate rises: invert two phases at the connection of the mains supply
When these tests are conclusive, the positioner is ready for starting-up. Repeat these checks each time the
positioner is moved.