D - ASSEMBLY - INSTALLATION
8695 6645 / C
D-16
POSIMATIC PS08
EXTERNAL CONNECTION FOR THE DIFFERENT OPTIONS
AUTO CONTROL
Emergency stop or external safety
Variable speed in service
External
POSIMATIC
startup
Pulse control
To select the Auto control of
POSIMATIC
Hold control
OPTIONAL ± 10V SETPOINT
Remove the two shunts
Connect the external ± 10v setpoint to terminals 24 and
23
-
to terminal 23
-
to terminal 24
To select an operating direction in the automatic mode
depending on the installed options, connect the
terminals:
- 148 and 44 for right - hand rotation
- 148 and 43 for left - hand rotation
- 148 and 53 for horizontal tilting
- 148 et 54 for vertical tilting