IS 745 ECN 4386
Page 8 of 12
A
B
Adjustment
– Pin Lock.
All units are fitted with a settings
PIN LOCK
. Press
READY
and then
Settings
to
access the
PIN
setting screen. The unit is fitted with an extra setting to lock the
dispense tap operation and an additional time setting that is used to set the
maximum time after the last dispense that the boiler is unlocked for. A master
PIN
code is available from Lincat Service should you forget the user set
PIN
.
Standby
If the appliance is to be left unused for any length of time, turn the element off by
pressing the
ON
/
OFF
button on the display.
Then press
OFF
. Now press <ENTER> to return to main display.
Filter replacement
The filter display shows the estimated life left in the filter cartridge. A reminder
message is displayed when the filter needs changing.
Fig. 4
To replace the filter
From the underside of the boiler loosen off screw
B
then slide and lift off cover
A
.
Twist the base of the filter 90° to the left and carefully lower the filter cartridge out of
the appliance. It will contain a small volume of water.
Re-insert new filter into the recess and lock into place by twisting to the right.
Replace cover
A
and tighten screw
B
.
Press the
filter life icon
and follow the on-screen instructions to reset the filter life.
Drain off approximately 3 litres of water to remove any loose carbon particles from
the filter.
The boiler will not fill if the filter is removed as the filter head incorporates a shut-off
valve.