IS 745 ECN 4386
Page 5 of 12
Hang the unit onto the bracket and mark the position of the lower fixing screw on
the underside of the unit. Remove the boiler and drill the hole and insert suitable
wall plug. The water boiler is now ready to mount and connect services.
Please allow 400mm clear space above the unit to allow removal of the cover and
300mm below the unit to allow for filter removal.
Electrical supply
The WMBFX wall mount series are supplied with a 13 amp plug to BS1363
Power Ratings
Model
kW
Amps
WMB5FX
3.0
13.0
Water Installation
Connect the supplied white water inlet hose to the inlet connection point on the
base of the boiler and the other end to the mains supply via an accessible isolating
tap with a
¾” BSP thread.
Use the hose set supplied with the appliance
– any previous hose set is not to be
re-used.
Connect the condensate/overflow pipe (Fig. 2 C) to a suitable drain, considering
any applicable local water regulations.
Potable water. If solid particles are known to be in the supply, add an extra inline
filter or strainer.
Ambient temp °C
Water inlet pressure Bar
Water inlet pressure kPa
5 to 30
1 to 8
100 to 800
Turn on the water supply and check for leaks.