IS355 ECN3592
12
SERVICING
ROUTINE SERVICE
We recommend that competent authorised service agents carry out all servicing,
other than routine cleaning. In addition to that, a service should take place every 6
months.
Please see page 18
“Service” for information on authorised service agents.
Carry out a general check on the installation paying particular attention to the
following:-
Has the unit been installed using the correct hose?
Does the unit have a safety chain?
Does the equipment have a separate isolation valve?
Check all components for correct operation and replace where necessary.
Visually check the burner operation, closely observing the flame picture and look for
evidence of any debris or damage. Remove burner and clean or replace as
necessary.
Check burner pressure and adjust
where necessary. See “insulation instructions”
Clean pilot assembly and check that it is burning cleanly.
Ensure that the flue is clear.
Carry out a gas soundness check.
SERVICE ACCESS
Note: Access to most of the components referred to in this section can only be gained by
separating the base/sides of the appliance from the tank assembly. See Base and hob top
separation
(Fig, 5)
BASE AND HOBTOP SEPARATION
Note: The fryer must be emptied of oil and disconnected from the gas supply before
proceeding.
Remove the control panel as per
(Fig1)
.
Detach the flue back by removing screws at back of unit holding flue to body.
Loosen the nut holding the drain tap valve to the drain tap bracket.
Remove the safety lock arm latch
(Fig 5, 1)
.
Undo the limit stat nut and free the limit stat.
Disconnect limit stat wiring to interrupted t/couple.
Disconnect the wiring from the control stat.