IS744 ECN 4665
Page 6 of 6
ACCESS THROUGH NARROW DOOR WAYS
The overall depth of the appliance (including door handles) is
825mm
.
This can be reduced further to an overall depth of
750mm
by the following steps.
1. Remove the pan supports, burner caps and oven shelves.
2. Using the cardboard packaging lay the appliance on its back in the cardboard
cap.
3. Remove the castors both front and back.
4. The appliance width will be reduced to
750mm
sufficient to pass through a
standard doorway of
770mm
.
Reassemble all parts when clearance is completed.
SITING
The installer must ensure that all local regulations are met and that there is an
unobstructed minimum distance of 1000mm from the top of the flue to the ceiling,
which must be of non-combustible material.
Install this appliance on a level surface ensuring all vents are unobstructed.
Any adjacent partitions, walls or furniture must be of non-combustible material otherwise
minimum distances = A, 50mm B, 1000mm
– see Fig 1
If this appliance is fitted with castors, use caution at all times when manipulating or
moving, and lock castors when appliance is in position.
The Installer shall pay particular attention, in order not to disturb the air combustion
admission nor the combustion products evacuation of appliances fitted with open
burners.
Fig 1
B
A