IS744 ECN 4665
Page 11 of 11
SERVICING AND MAINTENANCE
All servicing, maintenance and component replacement on this appliance should be
carried out by one of our recommended service engineers.
The electrical supply must be isolated before removing any
exterior panels
SERVICE ACCESS
To gain access gas control valves remove
the control knobs (A) by pulling free from
spindles.
Note: Spring clips are fitted in each knob
core; care should be taken to avoid loss.
Remove the three screws (B) directly
beneath the fascia panel.
Tilt the fascia panel at its base and pull
forward.
Note: Wiring will still be connected to
neons, thermostat and switch.
Servicing the Hob Burner Gas Taps -
Recommended every 6 months
To service the gas tap remove the two
screws (C) from the cap.
Carefully remove the cap and valve
spindle assembly.
Grease the components ensuring any
excess grease does not block valve ports.
Re-assemble the spindle and cap.
Check the valve spindle for free rotation.
Perform a gas soundness check
B
A
C
AA
Fig 4
Fig 5