IS 193 ECN 3607
Page 5 of 10
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60 Deg C
.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Connection of the electrical supply cable is at the rear of the appliance. Open the
protective cover using a small flat bladed screwdriver and fit a suitable cable into
the strain relief and then to the inlet terminal block. Secure the earth to the earth
stud. The appliance is supplied for connection to a three-phase supply.
The OE7205 can be installed on a single phase supply by linking L1 and L2.
OPERATING INSTRUCTIONS
Only qualified or trained personnel should use this appliance.
Griddle plate preparation
Before first use, wipe off protective oil from the plate and wash it down with a warm
detergent solution. Prepare the plate as follows:
Spread approximately 2kg of household salt evenly over the plate. Turn the
appliance on full.
Run the appliance for 30 minutes until the salt discolours.
Turn the appliance off, allow the plate to cool and discard the salt.
The plate is now ready for cooking.