LINAK.COM

/TECHLINE

SMPS-T160 

User manual

Содержание SMPS-T160

Страница 1: ...LINAK COM TECHLINE SMPS T160 User manual ...

Страница 2: ... 10 Output 11 System example 11 System combination possibilities 12 13 Connection diagram Single run 14 Connection diagram Single run LA35 IC 15 Connection diagram two actuators run individually 16 Connection diagram simultanious or parallel run 17 Cables 18 19 Dimensions 20 21 Label for SMPS T160 22 Key to symbols 22 Ordering example 23 Chapter 5 Maintenance cleaning 24 Repair 24 Main groups of d...

Страница 3: ...leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is s...

Страница 4: ...s will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that...

Страница 5: ...er Manual System connection The individual parts must be connected before the SMPS T160 is connected to the mains During operation Ensure that the cables are not damaged Unplug the SMPS T160 before moving the equipment If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged The product must only be used in an environment t...

Страница 6: ...standards like the Machine Directive Care must be taken to avoid squeezing of cables as it can cause movement of the system The SMPS T160 must not be packed in heat insulating material but must be placed so that it can emit waste heat to the surroundings There are no ventilation holes to consider the SMPS emits heat through its surface Page 6 of 28 Be aware of the following three symbols throughou...

Страница 7: ...ome precaution and design the wire connection in a way where the cable end is kept inside a closed protected area to guarantee the high IP protection Different bracket types are available to know more please contact your local LINAK supplier Page 7 of 28 1 Unscrew the cable lock 2 Plug in the power cable 3 Screw the cable lock back on 4 Unscrew the cable lock 6 Remove the plugs according to the nu...

Страница 8: ...p signals are NOT potential free For further information see the relevant I O specifications scheme in the actua tor s user manual Yellow Endstop signal in Violet Analogue feedback Hall Pot Configure any high low combination between 0 10V For further information see the rel evant I O specification s scheme in the actuator s user manual Single Hall output PNP Digital output feedback PWM Configure a...

Страница 9: ...utomatically reengage after few minutes Slow moving actuator The output power has been reduced due to high internal temperature Actuator is overloaded The actuator has exceeded the accepted duty cycle 10 The ambient temperature is too high Can be caused by direct sun light impact The power supply will switch back to normal power when the temperature has dropped again No power for the hand control ...

Страница 10: ...mospheric pressure 700 to 1060 hPa Altitude Max 2000 metres above sea level To extend retract the actuator A voltage greater than 21 V DC must be applied to red black wire To stop extending retracting the actuator A voltage less than 9 V DC must be applied to red black wire normally 0 V DC Approvals The SMPS T160 is approved according to the following standards 2004 108 EC EMC Directive 2006 95 EC...

Страница 11: ...se be aware if connecting an external control to an SMPS configured with an output interface Hand control The unit connected should be capable of tolerating overvoltage caused by soft stopping actuators Overvoltage caused by soft stopping actuators can reach up to 38 V Furthermore please be aware that the supply to control units are limited to 300 mA each ...

Страница 12: ...droid TR LMC2015 EU Market 868 3MHz US market 916 MHz RF receiver TR TVPLRX868A02 TR TVPLRX916A02 TXP transmitter TR TVTXP868A02 TR TVTXP916A02 EVO transmitter TR TVEVO868N03 TR TVEVO916S03 HB40 HB4X051 01 DP DP042 00 Standard TECHLINE signal cables See the table TECHLINE signal cables on page 20 For more information please go to www linakthirdparty com Page 12 of 28 LA12 ICTM LA23 ICTM ...

Страница 13: ...System combination possibilities LA35 IC SMPS T160 LA35 ICTM Signal cable Type Article No Standard TECHLINE signal cables See the table TECHLINE signal cables on page 20 Page 13 of 28 ...

Страница 14: ...14 ICTM LA25 ICTM Bluetooth receiver RF receiver HB40 DP Signal cable For more information on the flying leads please see the I O specifications in the user manual for the chosen actuator Fig 1 SMPST160 6UX0X0 Page 14 of 28 LA12 ICTM LA23 ICTM ...

Страница 15: ...that it is only possible to connect one actuator LA35 IC and flying leads to this system For more information on the flying leads please see the I O specifications in the LA35 user manual Fig 2 SMPST160 6UX0X0 Flying leads LA35 ICTM SMPS T160 Page 15 of 28 ...

Страница 16: ...either two identical IC actuators e g LA14 IC and LA25 IC in the two actuator sockets OR two different IC actuators You will need one control for each actuator BT RF HB DP flying leads For more information on the flying leads please see the I O specifications in the the user manual for the chosen actuator Fig 3 SMPST160 6UX0X0 Please be aware Page 16 of 28 LA12 ICTM LA23 ICTM ...

Страница 17: ...A14 IC LA23 IC or LA25 IC You will need one control for each actuator BT RF HB DP flying leads For more information on the flying leads please see the I O specifications in the the user manual for the chosen actuator Fig 4 Simultanious SMPST160 6UX2X0 BT RF HB DP SMPST160 6UX4X0 flying leads Parallel SMPST160 6UX4X0 BT RF HB DP SMPST160 6UX5X0 flying leads Please be aware Page 17 of 28 LA12 ICTM L...

Страница 18: ...75mm2 Black 3200 Straight EU SML912098 PVC 3 0 75mm2 Black 3200 Straight angle Actuator Plug types Article No Material Wires Size Colour Length mm Cable type LA14 IC LA25 IC Minifit 1008w7200 300 PVC 8 18AWG Black 300 Straight LA14 IC LA25 IC Minifit 1008w7200 1500 PVC 8 18AWG Black 1500 Straight LA12 IC Minifit 012913 PVC 8 22AWG Black 1500 Straight LA23 IC Minifit 0237084 PVC 8 20 24AWG Black 15...

Страница 19: ...erial Wires Size Colour Length mm Cable type Flying leads 0367049 1500 PVC 6 20AWG Black 1500 Straight Flying leads 0367049 5000 PVC 6 20AWG Black 5000 Straight The cable comes with an AMP connector that can be removed for flying leads Page 19 of 28 ...

Страница 20: ...Dimensions Without brackets With short brackets 249 45 78 awing No SMPS T160_LONG_BRACKETS 249 261 250 6 45 78 35 4 5 awing No SMPS T160_LONG_BRACKETS Page 20 of 28 ...

Страница 21: ...With long brackets 249 261 250 6 67 6 45 4 5 78 Page 21 of 28 ...

Страница 22: ... code 2 Prod Date YYYY MM DD Production date describes when the product has been produced This date is the reference for warranty claims 4 Output 29VDC 5 5A IPX6 Class 2 power supply Describes the maximum load that the product can be exposed to in compression and tension This line also contains a reference to the product s IP protection degree Key to symbols The following symbols are used on the S...

Страница 23: ...0mm 5 Australia 3200mm Output interface 0 Standard 1 Hand control Bracket 0 None 1 Short 1008w1051 2 Long 1008w1052 Input voltage U Universal 100V 240V Ingress protection 6 IP66 Colour Dark Olivish Grey Variant T160 160 W Type SMPS Switch Mode Power Supply 2 Hand control simultaneously 3 Hand control parallel 4 Standard simultaneously 5 Standard parallel Page 23 of 28 ...

Страница 24: ... our product is disassembled as much as possible at the disposal and that you try to recycle it Product Metal scrap Cable scrap Electronic scrap Plastic recycling or combustion SMPS T160 X X X X Main groups of disposal Repair Only an authorised LINAK service centre should repair LINAK SMPS T160 Products to be repaired under warranty must be sent to an authorised LINAK service centre In order to av...

Страница 25: ... to following standards EN 61000 6 1 2007 EN 61000 6 3 2007 complies with Low Voltage Directive 2014 35 EU according to the standard EN 61558 2 16 2009 complies with RoHS2 Directive 2011 65 EU according to the standard EN 50581 2012 Nordborg 2014 12 05 LINAK A S John Kling B Sc E E Certification and Regulatory Affairs Authorized to compile the relevant technical documentation Original Declaration ...

Страница 26: ... 1 Electricity supply The relevant technical documentation is compiled in accordance with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically to a reasoned request by the national authorities This partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conform...

Страница 27: ...Page 27 of 28 ...

Страница 28: ...4786428 E mail info linak in www linak in Ireland LINAK UK Limited Ireland Tel 44 0 121 544 2211 Fax 44 0 121 544 2552 44 0 796 855 1606 UK Mobile 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk Italy LINAK ITALIA S r l Tel 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it Japan LINAK K K Tel 81 45 533 0802 Fax 81 45 533 0803 E mail linak...