Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, category CAT III 1000V,
CAT IV 600V over voltage and double insulation.
Warning
To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or
to the equipment under test, adhere to the following rules:.
• Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or
part of the case) is removed. Look for cracks or missing plastics. Pay attention to the insulation
around the connectors.
• Inspect the test leads for damages insulation or exposed metal. Check the test leads for
continuity.
• Do not apply more than the rated voltage, as marked on the Meter, between the terminals or
between any terminal and the grounding.
• The rotary switch should be placed in the right
position and no any changeover of range shall be
made during measurement is conducted to prevent damage of the Meter.
• When the Meter working at an effective voltage over 60V in DC or 42V rms in AC, special care
should be taken for there is danger of electric shock.
• Do not use or store the Meter in an environment of high temperature; humidity, explosive,
inflammable and strong magnetic fields. The performance of the Meter may deteriorate after
dampened.
• When using the test leads, keep your fingers behind the finger guards.
• Disconnect circuit power and discharge all high-voltage capacitors before testing resistance,
continuity, diodes and current.
• Before measuring current, check the Meter fuses and turn off power to circuit before connecting
the Meter to the circuit.
• Replace the battery as soon as the battery indicator appears. Whit to low battery, the Meter
might produce false readings that can lead to electric shock and personal injury.
Functional buttons
RANGE
• Selection auto range or manual rangeing.The instrument always start with
auto range. In auto range the instrument always select the best range for input
signals.
Display shows AUTO.
• Push button to step through the ranges available for selected function. Push button
2 sec to return to auto range.
MAX/MIN
• Select max or min value. Push button for 2 sec for quite max/min function
REL
ǻ
• Relative mode applies to all function except frequency/duty cycle. Displays shows
ǻ
when relative function is on.
• On/Off for enter USB connection to PC. Push button for 2 sec for enter.
Hz%
• Select measuring frequency in Hz or duty cycle in % when rotary switch is in Hz
position.
• When measuring V, µA, mA or A also frequency or duty cycle can be displayed
by push the Hz% button. Push button by step between frequency, duty cycle or
return to previous measurement mode.
Yellow
• ON/OFF for hold function. H shows on display when value is frozen.
• ON/OFF for backlight. Push button for 2 sec for backlight.
Blue
• Selection of function when there are more than one function for rotary switch.
Содержание 610
Страница 1: ......
Страница 2: ...1 Illustrations Fig 4 Fig 5 Fig 6 Fig 3 Fig 2 Fig 1 ...
Страница 3: ...Tables ...
Страница 4: ...Tables ...
Страница 5: ...Tables ...
Страница 94: ......
Страница 95: ......
Страница 96: ......