Wiring Diagram 

 

Attention 

Set U34 correctly, otherwise system does not work correctly. 

The real clock can only keep running correctly for 72 hours after power supply loses. 

All sensors must be installed at correct position. 

Do not plug in/out panel bundle with power supplied. 

Panel should be installed indoors, instead of outdoors. 

Содержание ZL-R200A

Страница 1: ...mpressor 15A Heating 8A Others 3A Failure Code No Code Failure No Code Failure 1 E01 Water container sensor failure 5 E05 Water flow warning 2 E02 Pipe Coil sensor failure 6 E06 High low pressure input warning 3 E03 Exhaustion sensor failure 7 E07 Data saving failure 4 E04 Outdoor sensor failure 8 E08 Communication failure Display Indication Icon Display Not shown Icon Displaying Not shown Online ...

Страница 2: ...High low pressure warning mode 0 2 0 Disable 1 Closed when warning 2 Open when warning 0 9 U52 Water flowing switch mode 0 2 0 Disable 1 Effective when closed 2 Effective when open 0 10 U80 Auto restart function 0 1 0 Disable 1 Enable 0 11 U81 Keypad lock 0 1 0 Unlocked 1 Locked 0 12 U90 passwords 00 99 11 Working Mode Press to switch between AUTO and SAVE working mode AUTO mode always heating acc...

Страница 3: ...pressor and outdoor fan stop 55 seconds later valve acts 5 seconds later start compressor Stop defrosting When T pip U32 or the compressor has been running for U33 stop defrosting Stop compressor 55 seconds later valve acts 5 seconds later start heating control Defrost after turning the system online When turn online if the T pipe U31 defrost 1st Timer Defrost If pipe sensor fails and the compress...

Страница 4: ...tly otherwise system does not work correctly The real clock can only keep running correctly for 72 hours after power supply loses All sensors must be installed at correct position Do not plug in out panel bundle with power supplied Panel should be installed indoors instead of outdoors ...