Restore to factory settings 

Keep

SET

and

depressed simultaneously for 2 seconds, display 

“UnL”.   

Press

twice, all settings will restore to factory default values. 

 

Wiring diagram 

Diagram one: heating by compressor 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Diagram two: heating by heater 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ZL-807A

Страница 1: ...2 0 4 Heat by electrical heater F02 1 4 Defrost F02 0 and under heating mode 4 Forced defrost F02 0 under heating mode 4 Fast launch Force the compressor energized 4 Pump control 4 External alarm input 4 Delay protection for compressor 4 Auto restart 4 Calibration 4 Waring for sensor failure 4 Restore to factory settings 5 Wiring diagram 5 Diagram one heating by compressor 5 Diagram two heating by...

Страница 2: ...With 2 sensors we can check outdoor pipe temperature Water pump on off control Compressor delay protection Instant start compressor Temperature calibration Sensor failure warning External warning input Auto restart for power supply failure Specification Power supply 100 240Vac 50 60Hz Outputs Compressor 40A 250Vac relay can drive 2HP compressor Valve Heater 5A 250Vac resistance Fan 5A 250Vac resis...

Страница 3: ...erature In online status short press will blinkingly show pipe temperature for 10 seconds Short press could stop show the pipe temperature Parameter code table Code Function Setting range Remark Factory set F01 Temperature control mode 0 1 0 constant temperature 1 cooling only 0 F02 Heating mode 0 1 0 by compressor 1 by electrical heater 0 F03 Hysteresis 0 1 20 0 1 0 F04 Calibration for water sens...

Страница 4: ... seconds start compressor heating after 30 seconds Fan stops during defrosting Forced defrost F02 0 under heating mode Keep and depressed simultaneously for one second to enter into forced defrosting Forced defrosting works the same way as periodical defrost Once launched forced defrost it will not stop till the full process finished Fan stops during forced defrosting Fast launch Force the compres...

Страница 5: ...Pages Restore to factory settings Keep SET and depressed simultaneously for 2 seconds display UnL Press twice all settings will restore to factory default values Wiring diagram Diagram one heating by compressor Diagram two heating by heater ...

Страница 6: ...ages Dimension Case size Embedded hole If the cable protection rubbers could be removed during installation Hole size 136 1 86 5 mm R 7 mm If the cable protection rubbers could not be removed during installation Hole size 135 1 90 5 mm R 6 mm ...

Отзывы: