background image

18

RE-CALIBRATION OF CRIMPING DIAMETER DIAL

NOTE: The crimping diameter dial has been calibrated at the factory during test run.

1. Re-calibrate the crimping diameter with ferrule 

(seamless steel tube), Ø 25 mm; wall 2 mm, by using 

the die set 32-19.

2. Set the dial at 1.0, so that the crimping diameter will be 

20 mm (see the adjacent picture) and lock the dial. 

Crimp the ferrule and measure the real diameter.

3. Remove the control dial knob  (avoid to turn the dial 

shaft at the same time).

4. Open the dial lock lever and set the real diameter into 

it (diameter of ferrule) relock it and install back.

5. Turn the dial to right diameter and crimp another 

ferrule. Now the machine has been calibrated and the 

real diameter should be the same than the diameter 

which state on the dial. If not, repeat from point 2 and 

be more careful when handling the dial.

6. After the adjustment, the crimping result should be the 

minimum nominal crimping diameter of each die set 

with the dial at 0.0.

GUARANTEE

The machines produced by Lillbacka Powerco Oy are guaranteed against defects in material and 

manufacture. Within the limits of the guarantee, the defective part will be replaced with a new one, or when 

possible, repaired free of charge.
The guarantee is valid for 12 months after commissioning, yet for a period not exceeding 18 months after 

delivery ex works Alahärmä, Finland.
The guarantee does not compensate for damage due to improper use, overload, neglect, or normal wear. 

Working and travelling costs as well as freight charges caused by guarantee repairs are not covered by the 

guarantee.
Guarantee repairs shall be carried out at Lillbacka Powerco Oy, Alahärmä, Finland, or by an authorized Finn-

Power service. In case guarantee repair is demanded, the customer has to prove that the machine is under 

guarantee.
LILLBACKA POWERCO OY DO NOT WARRANT FOR ANY INCIDENTAL OR CONSEQUENTIAL 

DAMAGAES, OR FOR ANY OTHER LOSS, DAMAGE OR EXPENSE OF ANY KIND, INCLUDING LOSS OF 

PROFITS.

19

TECHNICAL DATA

TECHNICAL DATA   P51

3-phase

Capacity

in

2½  (industrial hose 4”)

Crimping diameter range *)

Ø (mm)

10....87

Max opening

mm

46

Pump

l/min

17/5.7

Max pressure

bar

300

Crimping force

kN

2800

Theoretical production capacity

per hour 

720

Sound pressure level

dB(A)

71

Enclosure class

IP 54

Closing speed of master dies (max.) mm/s

7.9
Frequency 50 Hz

Motor power

kW

4

Voltage V / Current A / Fuse A

  230 / 15.3 / 25

  400 /  8.8 / 20

        /       /

Frequency 60 Hz

Motor power

kW

4.8

Voltage V / Current A / Fuse A

  230 / 15.2 / 25

  400 / 8.7 / 20

        /        /

*) with complete standard die equipment.

Special diameters and profiles to customer's specifications.

Overall dimensions:

Weight 260 kg, excluding oil.

READ THE INSTRUCTIONS THOROUGHLY TO SECURE SAFE AND CORRECT 

OPERATION OF THE MACHINE.

Содержание Finn-power P51MS

Страница 1: ......

Страница 2: ......

Страница 3: ...retrieval systems The material in this documentation is subject to change without notice Keep this manual for future needs THE MACHINE HAS BEEN DESIGNED FOR CRIMPING HYDRAULIC FITTINGS LILLBACKA POWER...

Страница 4: ...ERATION 10 CONTROL IDENTIFICATION 10 TEST RUN 10 SELECTING THE DIE SET 11 FP140 DIE SETS 11 INSTALLING THE DIE SET 12 QUICK CHANGE 12 CHANGE OF A SINGLE DIE 12 SETTING THE CRIMPING DIAMETER 13 FINAL D...

Страница 5: ...tion is effective for months if the package is not opened After opening it the protection of the wrapping film ceases If the machine is not yet brought into use it must be reprotected against corrosio...

Страница 6: ...users own risk and recourse Read the instructions thoroughly to secure safe and correct operation of the machine The machine is intended for professional use It is to be operated only by a trained op...

Страница 7: ...s open and close by depressing the hand emergency push buttons at both ends of the valve Do not touch these push buttons during normal operation WARNING 4 High voltage The electric box can be opened o...

Страница 8: ...8 DANGER ZONES...

Страница 9: ...the earth connection to the ground terminal on the fixing plate Check the connection against the wiring diagram enclosed in the spare parts list RUNNING IN Recommended running in period for a new mach...

Страница 10: ...he maximum retraction is reached 4 Crimping diameter dial 5 Die chart with crimping diameter range for each die set and corresponding dial adjustment values The main operating area of the machine is i...

Страница 11: ...s are manufactured with following dimensions D L Die set No Crimping range 84 110 18860 84 84 92mm 92 110 18860 92 92 100mm 100 110 18860 100 100 108mm 108 110 18860 108 108 116mm 116 110 18860 116 11...

Страница 12: ...y until the pins are locked in their places Fig 3 Remove the tool Fig 4 Open the dies to the retraction position The dies are now ready for use Die set is removed from the master dies in reverse order...

Страница 13: ...give the crimping diameter 20 6 mm 19 1 6 mm The machine has been calibrated at the factory with 40 bar pressure This means that when you are crimping a fitting requiring 40 bar pressure the measuring...

Страница 14: ...the preset diameter has been reached The crimping movement stops automatically and light goes on in the crimping push button Depress the retraction button and take the crimped assembly out Check the...

Страница 15: ...e leaked inside the machine and then slowly under the machine 3 If the machine is in continuous use some oil 0 1dl might pass the seals and leak under the cylinder when the machine is stopped or when...

Страница 16: ...machine always clean Clean machine ensures nice and safe operation Wipe the machine with dry cloth or with soft paper Do not use water solvents or abrasives Fig 1 Fig 2 The inner side of the crimping...

Страница 17: ...the seal of the new filter insert with hydraulic oil Screw the filter insert on MASTER DIE SPRING CHANGE Master die springs are wearing parts and therefore has to be replace after every 200 000 crimps...

Страница 18: ...ng result should be the minimum nominal crimping diameter of each die set with the dial at 0 0 GUARANTEE The machines produced by Lillbacka Powerco Oy are guaranteed against defects in material and ma...

Страница 19: ...1 Enclosure class IP 54 Closing speed of master dies max mm s 7 9 Frequency 50 Hz Motor power kW 4 Voltage V Current A Fuse A 230 15 3 25 400 8 8 20 Frequency 60 Hz Motor power kW 4 8 Voltage V Curren...

Страница 20: ...ure class IP 54 Closing speed of master dies max mm s 7 9 Frequency 50 Hz Motor power kW 4 Voltage V Current A Fuse A 230 15 3 25 400 8 8 20 Frequency 60 Hz Motor power kW 4 8 Voltage V Current A Fuse...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ......

Страница 24: ......

Отзывы: