SMAX MODBUS®
HW Version [0005 hex]
[Register 6, Unsigned16, ro]
This is meant to show the hardware (PCB) version of the encoder.
The major number shows the hardware edition, while the minor number shows
the hardware revision.
The meaning of the 16 bits in the register is as follows:
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Ms bit
Ls bit
Major number
Minor number
Value 01 01 hex in hexadecimal notation corresponds to the binary
representation 00000001 00000001 and has to be interpreted as: hardware
edition 01, hardware revision 01.
Status word [0006 hex]
[Register 7, Unsigned16, ro]
This register contains information about the current state of the device. The
eight bits of Byte 0 (LSB) shows the currently set values of the
register Byte 0 (LSB); while bit 8 of MSB is used to
signal active alarms.
Byte structure of the
register:
byte
MSB
LSB
bit
15
…
8
7
…
0
msb
lsb
msb
lsb
Byte 0
Scaling
bit 0
It shows the value which is currently set next to the
parameter. In other words, it is
intended to show whether the scaling function is
enabled or disabled. If the value is “=0” the scaling
function is disabled; if the value is “=1” instead the
scaling function is enabled. For any further
information on setting and using the scaling function
refer to the
Counting direction
bit 1
It shows the value which is currently set next to the
parameter. If the bit is “=0” the
MAN SMAX MB E 1.2
Programming parameters
72 of 84
Содержание SMAX-AI1-PRG-L2
Страница 82: ...This page intentionally left blank...