Hall sequence
bit 14
An error has been detected in the Hall sensors commutation
sequence.
Overvoltage
bit 15
The power supply voltage is over the maximum ratings
allowed. Please ensure that the power supply voltage is
within the range.
If the alarm is triggered during the braking operation, please
consider the counter-electromotive force (back EMF). To
prevent such situation from arising, decrease the
deceleration ramp or evaluate attentively the characteristics
of the 24V power supply pack (capacitor module).
To reset a faulty condition use the
bit 3. In a normal work condition the
Setting the bit to “1” causes the normal work status of the device to be restored.
The normal work status is resumed by switching this bit from “0” to “1”. This
command resets the alarm but only if the fault condition has ceased.
Please note that should the alarm be caused by wrong parameter values (see
Wrong parameters list [0x08-0x09]
), the
normal work status can be restored only after having set proper values. The
alarm cannot be reset.
Status word [0x01]
[Register 2, Unsigned16, ro]
This register contains information about the current state of the device.
Byte structure of the
register:
byte
MSB
LSB
bit
15
…
8
7
…
0
msb
lsb
msb
lsb
Byte 0
Axis in position
bit 0
The value is “=1” when the device reaches and keeps
the set position (
) for
the time set next to the
register. It is kept active until the position
error is lower than
. For
MAN RD6 MB E 1.1
Programming parameters
77 of 92
RD6 Modbus®