Value 18 1A hex in hexadecimal notation corresponds to the binary
representation 0001 1000 0001 1010 and has to be interpreted as: temperature
of the motor = 24°C; temperature of the electronics = 26°C.
Wrong parameters list [0x08-0x09]
[Registers 9-10, Unsigned32, ro]
The operator has set invalid data and the
been triggered. This variable is meant to show the list of the wrong parameters,
respecting the structure shown in the following table.
Please note that the normal work status can be restored only after having set
proper values.
Bit
Parameter
0
Not used
1
Distance per revolution [0x00]
2
3
4
5
6
7
8
9
10
11
12
13
14 and 15
Not used
Motor voltage [0x0A]
[Register 11, Unsigned16, ro]
It shows the motor voltage expressed in millivolts (mV).
MAN RD6 MB E 1.1