SMRA - SSI and BiSS
3.3 Installing the system
Figure 2
3.3.1 Mounting the magnetic ring
1. Mount the magnetic ring
2
on the motor shaft;
2. mount the locking ring
3
and fasten the whole assembly to the motor
shaft by using six bolts type M3 x 20 UNI7688. Tighten the bolts
following the sequence indicated in the Figure. Recommended
tightening torque:
1.1 Nm
.
3.3.2 Mounting the sensor
1. Fix the sensor
1
using two cylinder head bolts M4 x 25 UNI5931.
Recommended tightening torque:
2.5 Nm
. Recommended
minimum
bend radius
of the cable:
R
42 mm
.
The max. allowed gap between the sensor and the magnetic ring is 1 ±0.2
mm (0.04” ±0.008”).
WARNING
Please be sure that the mounting tolerances indicated in Figure 3 are always
met. Avoid contact between the parts.