LD25x
4.6 Serial RS-232 / RS-485 interface (LD253 model only)
Ex factory the unit is set to RS-232 communication. This setting can be changed
to RS-485 (2-wire) by means of an internal DIL switch. To access the DIL switch,
you must remove the screw terminal connectors and the back panel. Then pull
the board to the rear to remove the PCB from its housing.
ON DIP
DIL-Switch
Removal of the back panel
Location of the DIL switch
RS-232
ON
8
9
10
RxD
TxD
GND
RS-485
ON
8
9
10
A (+)
B (-)
GND
WARNING
1. Never set DIL switch positions 1 and 2 or DIL switch positions 3 and 4 to
ON at the same time!
2. After setting the switch, shift the print carefully back to its housing, in
order to avoid damaging the front pins for connection with the front
keypad plate.
Connection of the RS-232 interface
Connection of the RS-485 interface
MAN LD25x E 1.0.odt
Electrical connections