LD25x
8.4.3 Operation with “Zero-Crossing”
As a special advantage, the “Round-loop” function mode can be used to bypass
the mechanical encoder overflow position, because in this mode the unit
continues with steady operation, even while the SSI encoder signal passes the
mechanical overflow position from maximum value back to zero.
This feature can help to avoid mechanical adjusting of the encoder zero position
with many applications, when no other means for the mechanical zero
definition is available.
As a general rule, the Reset input will be used to define the zero position. The
following picture explains the details of this operation.
8192
3500
r-LooP = 6000
0-PoS = 3500
Original encoder signal
Display
360
o
degrees
0
o
Overflow
Encoder: 13 Bit
Direction = 0
r-LooP = 6000
0-PoS = 3500
Overflow suppression with a 13-bit SSI encoder
8.4.4 Splitting of SSI encoder information into two separate displays
The “Bit Blanking” function also allows to distribute one SSI telegram to two
different SSI indicator units. As a typical application the figure below shows
how to separate the angular information within one turn and the number of
turns in a 16 x 16 multi-turn encoder.
Multiturn SSI
16 + 16 = 32 Bit
Master: bits 17 - 32
(number of turns)
Slave: bits 01 - 16
(angular position)
Parameters:
Bits = 32
HiBit = 32
LoBit = 17
Parameters:
Bits = 32
HiBit = 16
LoBit = 01