AMM8A SSI & BiSS C-mode
IF90 not connected
The operator has pressed the
CONNECT
button in order to establish the
connection to the encoder but a fault has occurred: the program is not able to
establish a connection to the IF90-SC interface. Please check that the EXC-
D15M-S71-A16-1,0-FCI-S71 cable is connected properly on both sides. Make
sure that the IF90-SC interface is powered and the power supply voltage is
correct. For any information please refer to the “6.3 Before launching the
calibration and synchronization procedure” section on page 39.
Synchronization OK
As soon as the synchronization procedure is carried out positively, a green tick (
) appears next to the
Synchronization single/multi turn
item and the
message is displayed. At the end of the positive procedure,
the encoder is ready for operation. For further information refer to the “6.5.7
Synchronizing singleturn and multiturn positions” section on page 47.
Zero setting OK
As soon as the zero setting operation is carried out positively, a green tick (
)
appears next to the
MAKE ZERO SETTING
message is displayed.
MAN AMM8A SSI_BiSS E 1.10.odt 6 - Calibration and synchronization procedure 53 of 80
Содержание AMM8A
Страница 78: ...This page intentionally left blank ...
Страница 79: ...This page intentionally left blank ...