AMM8A SSI & BiSS C-mode
Step 7
After installing the encoder unit
5
, it is necessary to carry out the procedure
meant to synchronize the gears and the single-multi turn information code.
The proper synchronization is achieved by uploading at power-on the offset
value calculated during the synchronization procedure.
Turn the power on.
WARNING
Never supply the encoder unit
5
if it is not installed on the code
disk
3
and can read it; the error that is generated cannot be reset.
Step 8
Start the motor running at an ideal speed of 60 ±10 rpm.
Check whether the
ERROR
LED
13
either is off or lights up solidly or blinks at
any point while the shaft is rotating.
The error condition is also signalled through the BiSS
bit (page 58, active
Step 9
If the
ERROR
LED
13
is off, jump to
Step 12
and proceed with the fast
synchronization procedure.
MAN AMM8A SSI_BiSS E 1.10.odt
4 - Mounting instructions
22 of 80