AM58K CANopen®
4 - Electrical connections
WARNING
Power supply must be turned off before performing any electrical connection!
4.1 Connection cap
WARNING
Do not remove or mount the connection cap with power supply switched ON.
Damage may be caused to internal components.
The terminal connectors for connecting the power supply and the BUS IN and
BUS OUT cables as well as the dip-switches meant to set the baud rate and the
node ID and activate the termination resistance are located inside the encoder
connection cap. Thus you must remove the connection cap to access any of
them.
NOTE
Be careful not to damage the internal components when you perform this
operation.
To remove the connection cap loosen the two screws
1
. Please be careful with
the internal connector.
Always replace the connection cap at the end of the operation. Take care in re-
connecting the internal connector. Tighten the screws
1
using a tightening
torque of approx. 2.5 Nm.
WARNING
You are required to check that the encoder body and the connection cap are at
the same potential before replacing the connection cap!